Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (560mm)
1
1
18-22AWG
No
4+4 pin EPS12V (735mm+145mm)
1
2
18AWG
No
6+2 pin PCIe (580mm+120mm)
1
2
18AWG
No
6+2 pin PCIe (580mm)
1
1
18AWG
No
12+2 pin PCIe (590mm) (600W)
1
1
16-26AWG
No
SATA (445mm+105mm+105mm+105mm) / 4-pin Molex (+100mm)
2
8 / 2
18AWG
No
Modular Cables
AC Power Cord (1395mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
SILVER
噪音評比
Standard+
Average Efficiency (>1450 load combinations)
86.252%
Average Noise Output (>1450 Load Combinations)
35.21dBA
Average PF (>1450 Load Combinations)
0.986
Efficiency With 10W (≤500W) or 2% (>500W) Load
61.262%
Standby Power Consumption
0.0311W
12V Ripple (Full Load)
33.00mV
5V Ripple (Full Load)
19.95mV
3.3V Ripple (Full Load)
18.49mV
5VSB Ripple (Full Load)
17.69mV
12V Load Regulation
0.68%
5V Load Regulation
0.45%
3.3V Load Regulation
0.76%
5VSB Load Regulation
3.59%
Inrush Current
16.040A
效率評比
SILVER
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
88.600%
Average Noise Output (>1450 Load Combinations)
34.65dBA
Average PF (>1450 Load Combinations)
0.949
Efficiency With 10W (≤500W) or 2% (>500W) Load
60.197%
Standby Power Consumption
0.0673W
12V Ripple (Full Load)
30.95mV
5V Ripple (Full Load)
18.24mV
3.3V Ripple (Full Load)
17.39mV
5VSB Ripple (Full Load)
13.92mV
12V Load Regulation
0.69%
5V Load Regulation
0.45%
3.3V Load Regulation
0.73%
5VSB Load Regulation
3.63%
Inrush Current
32.620A
12V Transient Response (200%)
11.35V
5V Transient Response (200%)
5.046V
3.3V Transient Response (200%)
3.223V
5VSB Transient Response (200%)
4.929V
Hold-Up Time & Power Ok Signal
15.80ms
AC Loss to PWR_OK Hold Up Time
14.40ms
PWR_OK Inactive to DC Loss Delay
1.40ms
PSU Timings: T1 (20% / 100%)
27.0ms
27.0ms
PSU Timings: T3 (20% / 100%)
117.0ms
118.0ms
OPP (25.64°C / 43.22°C)
115.51%
121.57%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
15.8
AC Loss to PWR_OK Hold Up Time (ms)
14.4
PWR_OK Inactive to DC Loss Delay (ms)
1.4
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.17 V
115.16 V
113.85 V
115.20 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.13 %
0.10 %
N/A
0.15 %
2.00 %
PASS
Real Power:
0.031 W
0.007 W
N/A
0.047 W
N/A
N/A
Apparent Power:
8.439 W
8.435 W
N/A
8.446 W
N/A
N/A
Power Factor:
0.005
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.38 V
230.38 V
227.70 V
230.42 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.14 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.067 W
0.057 W
N/A
0.079 W
N/A
N/A
Apparent Power:
28.249 W
28.236 W
N/A
28.264 W
N/A
N/A
Power Factor:
0.002
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input