| 115V | 230V | |
| Scheme: ETA-EMI PSU | ![]() |
![]() |
| 115V | 230V | |
![]() |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 400 RPM · <6.0 dB(A) · 40.2 °C | 400 RPM · <6.0 dB(A) · 40.2 °C | <6.0 in both |
| 20% | 401 RPM · <6.0 dB(A) · 40.7 °C | 401 RPM · <6.0 dB(A) · 40.7 °C | <6.0 in both |
| 50% | 446 RPM · 7.2 dB(A) · 42.5 °C | 446 RPM · 7.2 dB(A) · 42.5 °C | +0.0 dB(A) |
| 100% | 2186 RPM · 50.2 dB(A) · 45.5 °C | 2186 RPM · 50.2 dB(A) · 45.5 °C | +0.0 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 399 RPM · <6.0 dB(A) · 40.4 °C | 399 RPM · <6.0 dB(A) · 40.4 °C | <6.0 in both |
| 20% | 400 RPM · <6.0 dB(A) · 40.6 °C | 400 RPM · <6.0 dB(A) · 40.6 °C | <6.0 in both |
| 50% | 598 RPM · 14.1 dB(A) · 42.0 °C | 598 RPM · 14.1 dB(A) · 42.0 °C | +0.0 dB(A) |
| 100% | 2197 RPM · 50.4 dB(A) · 45.5 °C | 2197 RPM · 50.4 dB(A) · 45.5 °C | +0.0 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.