Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (495mm)
1
1
16-22AWG
No
4+4 pin EPS12V (550mm)
1
1
16AWG
No
8 pin EPS12V (550mm)
1
1
16AWG
No
6+2 pin PCIe (550mm)
4
4
16AWG
No
12+4 pin PCIe (720mm) (600W)
1
1
16-26AWG
No
2x SATA (400mm+125mm)
1
4
18AWG
No
SATA (305mm+15mm+15mm+15mm)
1
4
18AWG
No
SATA (405mm+150mm+150mm+150mm)
2
8
18AWG
No
SATA (455mm+150mm) /4-pin Molex (+150mm+150mm)
1
2 / 2
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
PLATINUM
Lautstärkeklasse
Standard++
Average Efficiency (>1450 load combinations)
89.595%
Average Noise Output (>1450 Load Combinations)
34.21dBA
Average PF (>1450 Load Combinations)
0.989
Efficiency With 10W (≤500W) or 2% (>500W) Load
73.670%
Standby Power Consumption
0.0129W
12V Ripple (Full Load)
30.93mV
5V Ripple (Full Load)
23.36mV
3.3V Ripple (Full Load)
17.02mV
5VSB Ripple (Full Load)
22.34mV
12V Load Regulation
0.42%
5V Load Regulation
0.74%
3.3V Load Regulation
1.02%
5VSB Load Regulation
2.40%
Inrush Current
16.230A
Wirkungsgrad
PLATINUM
Lautstärkeklasse
Standard++
Average Efficiency (>1450 load combinations)
91.835%
Average Noise Output (>1450 Load Combinations)
33.79dBA
Average PF (>1450 Load Combinations)
0.970
Efficiency With 10W (≤500W) or 2% (>500W) Load
72.947%
Standby Power Consumption
0.1009W
12V Ripple (Full Load)
31.13mV
5V Ripple (Full Load)
21.54mV
3.3V Ripple (Full Load)
16.33mV
5VSB Ripple (Full Load)
20.54mV
12V Load Regulation
0.44%
5V Load Regulation
0.76%
3.3V Load Regulation
1.02%
5VSB Load Regulation
2.44%
Inrush Current
24.690A
12V Transient Response (200%)
11.38V
5V Transient Response (200%)
4.869V
3.3V Transient Response (200%)
3.171V
5VSB Transient Response (200%)
4.876V
Hold-Up Time & Power Ok Signal
23.90ms
AC Loss to PWR_OK Hold Up Time
21.30ms
PWR_OK Inactive to DC Loss Delay
2.60ms
PSU Timings: T1 (20% / 100%)
59.0ms
59.0ms
PSU Timings: T3 (20% / 100%)
121.0ms
123.0ms
OPP (28.82°C / 42.61°C)
136.24%
127.16%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
23.9
AC Loss to PWR_OK Hold Up Time (ms)
21.3
PWR_OK Inactive to DC Loss Delay (ms)
2.6
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.07 V
115.03 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.013 W
0.008 W
N/A
0.017 W
N/A
N/A
Apparent Power:
7.026 W
6.928 W
N/A
7.112 W
N/A
N/A
Power Factor:
0.002
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.00 V
230.89 V
227.70 V
231.07 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.28 %
2.00 %
PASS
Real Power:
0.101 W
0.085 W
N/A
0.243 W
N/A
N/A
Apparent Power:
23.263 W
23.068 W
N/A
23.464 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input