Aristeidis Bitziopoulos, Certification Body General Manager
General Information
Main Specs
Product Identification Details
Brand
Cooler Master
Model
MWE Bronze 550 V3 230V
OEM
Gospower
Serial Number
MPE5501ACABW3BEU1241500002
Product Specifications
Manufacturer
Rated Voltage (Vrms)
200-240
Rated Current (Arms)
5
Rated Frequency (Hz)
50-60
Rated Power (W)
550
Operating Temperature (Continuous Full Load) (°C)
Type
ATX12V
Cable Design
Fixed cables
Warranty
-
Cybenetics
Dimensions (W x H x D)
Weight
Cooling
120mm Fluid Dynamic Bearing Fan (HA1225H12F-Z)
Semi-Passive Operation
✓
Cybenetics Testing Information
Lab ID
CM55002483
Date of receipt
May 29, 2024
Testing Date
Jun 19, 2024
Report Issued Date
Jun 20, 2024
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 24 pin (500mm)
1
1
18AWG
No
4+4 pin EPS12V(570mm)
1
1
18AWG
No
6+2 pin PCIe (545mm+100mm)
1
2
16-18AWG
No
SATA (430mm+150mm+150mm)
2
6
18AWG
No
4-pin Molex (430mm+150mm+150mm)
1
3
18AWG
No
Modular Cables
AC Power Cord (1380mm) - C13 coupler
1
1
18AWG
-
Protection Features(Non-accredited measurements)
Over Power Protection
✓
Over Current (+12V) Protection
✓
Over Temperature Protection
✓
Short Circuit Protection
✓
Surge Protection
✓
Inrush Current Protection
✓
Fan Failure Protection
✗
Power Specifications(Manufacturer)
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
17
17
45
3
0.3
Watts
110
540
15
3.6
Total Max. Power (W)
550
Parts Description
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
87.453%
Average Noise Output (>1450 Load Combinations)
27.29dBA
Average PF (>1450 Load Combinations)
0.942
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1777W
Non-Accredited
12V Ripple (Full Load)
44.61mV
5V Ripple (Full Load)
18.04mV
3.3V Ripple (Full Load)
18.13mV
5VSB Ripple (Full Load)
51.14mV
12V Load Regulation
1.66%
5V Load Regulation
2.73%
3.3V Load Regulation
3.47%
5VSB Load Regulation
3.98%
Inrush Current
Too low to detect
12V Transient Response (150%)
11.72V
5V Transient Response (150%)
4.959V
3.3V Transient Response (150%)
3.233V
5VSB Transient Response (150%)
4.984V
Hold-Up Time & Power Ok Signal
24.50ms
AC Loss to PWR_OK Hold Up Time
22.80ms
PWR_OK Inactive to DC Loss Delay
1.70ms
PSU Timings: T1 (20% / 100%)
55.0ms
56.0ms
PSU Timings: T3 (20% / 100%)
114.0ms
114.0ms
12V OCP (28.1°C / 43.0°C)
68.60A (152.44%), 11.880V
63.20A (140.44%), 11.915V
5V OCP (28.1°C / 43.0°C)
25.4A (149.41%), 4.966V
25.7A (151.18%), 4.962V
3.3V OCP (28.1°C / 43.0°C)
30A (176.47%), 3.292V
30A (176.47%), 3.291V
5VSB OCP (28.1°C / 43.0°C)
4.5`A (150.00%), 4.998V
4.3A (143.33%), 4.989V
OPP (27.96°C / 43.62°C)
150.17%
142.71%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
24.5
AC Loss to PWR_OK Hold Up Time (ms)
22.8
PWR_OK Inactive to DC Loss Delay (ms)
1.7
Stromverbrauch im Ruhezustand
Tables 230V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.02 V
230.93 V
227.70 V
231.09 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.15 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.178 W
0.139 W
N/A
0.241 W
N/A
N/A
Apparent Power:
51.973 W
51.669 W
N/A
52.321 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input