Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (300mm)
1
1
16-18AWG
No
4+4 pin EPS12V (400mm)
2
2
16AWG
No
6+2 pin PCIe (400mm+150mm)
1
2
18AWG
No
12+4 pin PCIe (450mm) (600W)
1
1
16-28AWG
No
SATA (300mm+155mm+155mm+155mm)
2
8
18AWG
No
4-pin Molex (300mm+150mm+150mm+150mm)
1
4
18AWG
No
AC Power Cord (1380mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Efficiency Rating
PLATINUM
Noise Rating
A
Average Efficiency (>1450 load combinations)
89.949%
Average Noise Output (>1450 Load Combinations)
20.31dBA
Average PF (>1450 Load Combinations)
0.988
Efficiency With 10W (≤500W) or 2% (>500W) Load
69.854%
Standby Power Consumption
0.0556W
12V Ripple (Full Load)
25.86mV
5V Ripple (Full Load)
0.00mV
3.3V Ripple (Full Load)
0.00mV
5VSB Ripple (Full Load)
10.55mV
12V Load Regulation
0.25%
5V Load Regulation
0.00%
3.3V Load Regulation
0.00%
5VSB Load Regulation
1.73%
Inrush Current
25.740A
Efficiency Rating
PLATINUM
Noise Rating
A+
Average Efficiency (>1450 load combinations)
91.862%
Average Noise Output (>1450 Load Combinations)
18.00dBA
Average PF (>1450 Load Combinations)
0.936
Efficiency With 10W (≤500W) or 2% (>500W) Load
68.733%
Standby Power Consumption
0.0971W
12V Ripple (Full Load)
26.76mV
5V Ripple (Full Load)
0.00mV
3.3V Ripple (Full Load)
0.00mV
5VSB Ripple (Full Load)
10.34mV
12V Load Regulation
0.25%
5V Load Regulation
0.00%
3.3V Load Regulation
0.00%
5VSB Load Regulation
1.73%
Inrush Current
94.920A
Hold-Up Time & Power Ok Signal
25.00ms
AC Loss to PWR_OK Hold Up Time
18.00ms
PWR_OK Inactive to DC Loss Delay
7.00ms
PSU Timings: T1 (20% / 100%)
101.0ms
99.0ms
PSU Timings: T3 (20% / 100%)
123.0ms
123.0ms
12V OCP (25.6°C / 43.9°C)
92.20A (130.23%), 12.294V
92.80A (131.07%), 12.294V
5V OCP (25.6°C / 43.9°C)
30.3A (151.50%), 4.98V
30.3A (151.50%), 4.977V
3.3V OCP (25.6°C / 43.9°C)
30.3A (151.50%), 3.331V
30.3A (151.50%), 3.329V
5VSB OCP (25.6°C / 43.9°C)
4.6A (153.33%), 5.068V
4.5A (150.00%), 5.068V
OPP (25.85°C / 43.92°C)
133.57%
135.34%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
25
AC Loss to PWR_OK Hold Up Time (ms)
18
PWR_OK Inactive to DC Loss Delay (ms)
7
Vampire Power
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.07 V
115.04 V
113.85 V
115.12 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.08 %
N/A
0.20 %
2.00 %
PASS
Real Power:
0.056 W
0.006 W
N/A
0.086 W
N/A
N/A
Apparent Power:
8.715 W
8.363 W
N/A
9.070 W
N/A
N/A
Power Factor:
0.008
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.06 V
230.96 V
227.70 V
231.11 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.15 %
N/A
0.25 %
2.00 %
PASS
Real Power:
0.097 W
0.072 W
N/A
0.176 W
N/A
N/A
Apparent Power:
28.663 W
28.177 W
N/A
29.175 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
NLO
✓
Fan Failure Protection
✗
SIP
Surge: MOV Inrush: NTC
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
5.155A
2.004A
1.965A
0.981A
85.005
85.464%
0
<6.0
50.01°C
0.951
12.300V
4.99V
3.359V
5.101V
99.462
40.14°C
115.16V
20%
11.307A
3.008A
2.951A
1.178A
169.961
90.57%
0
<6.0
50.81°C
0.983
12.299V
4.989V
3.355V
5.093V
187.658
40.94°C
115.13V
30%
17.803A
3.51A
3.445A
1.377A
254.966
91.46%
0
<6.0
52.21°C
0.989
12.296V
4.987V
3.352V
5.085V
278.77
41.11°C
115.1V
40%
24.310A
4.013A
3.941A
1.576A
340.054
91.894%
0
<6.0
54.51°C
0.992
12.293V
4.985V
3.349V
5.078V
370.047
41.78°C
115.09V
50%
30.470A
5.018A
4.933A
1.776A
424.99
91.81%
1266
19.9
42.28°C
0.994
12.290V
4.983V
3.345V
5.07V
462.901
49.59°C
115.06V
60%
36.599A
6.024A
5.925A
1.976A
509.501
91.515%
1491
24.8
42.62°C
0.994
12.287V
4.981V
3.342V
5.062V
556.743
49.96°C
115.03V
70%
42.800A
7.031A
6.921A
2.177A
594.844
91.1%
1751
29.4
43.12°C
0.995
12.284V
4.98V
3.338V
5.054V
652.958
50.85°C
115.01V
80%
49.000A
8.037A
7.916A
2.279A
679.657
90.482%
1990
33.1
43.6°C
0.996
12.281V
4.977V
3.334V
5.046V
751.157
52.1°C
114.99V
90%
55.595A
8.542A
8.404A
2.381A
765.065
89.982%
2234
36.6
44.65°C
0.996
12.277V
4.975V
3.331V
5.04V
850.244
53.32°C
114.96V
100%
61.936A
9.049A
8.924A
2.984A
849.919
89.201%
2551
39.8
45.77°C
0.996
12.274V
4.973V
3.328V
5.027V
952.813
55.29°C
114.94V
110%
68.150A
10.058A
10.017A
2.988A
934.513
88.274%
2556
39.8
46.61°C
0.995
12.270V
4.971V
3.324V
5.021V
1058.663
57.63°C
114.92V
CL1
0.114A
12.432A
12.215A
0A
104.299
82.743%
1445
23.6
40.54°C
0.963
12.300V
4.987V
3.348V
5.102V
126.054
48.17°C
115.14V
CL2
0.114A
20.028A
0A
0A
101.395
82.394%
1221
19
40.68°C
0.964
12.302V
4.993V
3.363V
5.107V
123.062
47.03°C
115.14V
CL3
0.113A
0A
19.74A
0A
67.386
75.606%
1099
15.8
40.18°C
0.945
12.300V
4.989V
3.343V
5.103V
89.127
45.79°C
115.15V
CL4
69.210A
0A
0A
0A
849.575
89.759%
2222
36.2
45.54°C
0.996
12.276V
4.981V
3.342V
5.066V
946.515
53.11°C
114.93V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
5.154A
2.004A
1.965A
0.98A
84.998
86.243%
0
<6.0
47.75°C
0.75
12.302V
4.99V
3.359V
5.101V
98.561
40.13°C
230.37V
20%
11.305A
3.007A
2.95A
1.178A
169.945
91.187%
0
<6.0
48.61°C
0.852
12.299V
4.988V
3.355V
5.093V
186.368
40.55°C
230.37V
30%
17.802A
3.51A
3.446A
1.377A
254.954
92.807%
0
<6.0
49.64°C
0.932
12.296V
4.986V
3.352V
5.085V
274.716
41.12°C
230.37V
40%
24.310A
4.013A
3.942A
1.576A
340.055
93.496%
1511
25
41.94°C
0.955
12.293V
4.984V
3.349V
5.078V
363.713
50.24°C
230.37V
50%
30.474A
5.019A
4.933A
1.776A
425.031
93.554%
1334
22.1
42.3°C
0.967
12.290V
4.982V
3.345V
5.069V
454.315
48.89°C
230.37V
60%
36.609A
6.025A
5.927A
1.976A
509.594
93.481%
1506
24.9
42.76°C
0.974
12.286V
4.981V
3.341V
5.061V
545.129
49.21°C
230.37V
70%
42.807A
7.032A
6.922A
2.177A
594.925
93.326%
1739
29.3
43.16°C
0.978
12.284V
4.979V
3.338V
5.053V
637.469
49.57°C
230.35V
80%
49.005A
8.038A
7.917A
2.279A
679.714
92.969%
1943
32.4
43.8°C
0.981
12.281V
4.977V
3.334V
5.046V
731.114
50.63°C
230.33V
90%
55.600A
8.543A
8.405A
2.381A
765.121
92.692%
2248
37.1
44.57°C
0.981
12.277V
4.975V
3.331V
5.039V
825.451
51.71°C
230.31V
100%
61.939A
9.05A
8.924A
2.984A
849.958
92.33%
2539
39.7
45.6°C
0.981
12.274V
4.973V
3.328V
5.027V
920.567
53.3°C
230.29V
110%
68.149A
10.058A
10.017A
2.988A
934.529
91.987%
2550
39.8
46.08°C
0.981
12.271V
4.971V
3.324V
5.021V
1015.943
54.13°C
230.28V
CL1
0.114A
12.432A
12.216A
0A
104.299
83.463%
1421
23.3
41.38°C
0.786
12.299V
4.987V
3.348V
5.102V
124.974
48.07°C
230.38V
CL2
0.114A
20.027A
0A
0A
101.395
82.931%
1166
17.5
40.69°C
0.782
12.302V
4.993V
3.363V
5.107V
122.265
46.65°C
230.38V
CL3
0.113A
0A
19.741A
0A
67.388
76.08%
1143
17
41.35°C
0.74
12.299V
4.989V
3.343V
5.103V
88.574
46.74°C
230.38V
CL4
69.214A
0A
0A
0A
849.607
93.059%
2194
35.6
45.65°C
0.982
12.276V
4.98V
3.341V
5.065V
912.986
51.62°C
230.29V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.206A
0.5A
0.49A
0.196A
19.998
71.712%
0
<6.0
40.9°C
0.811
12.305V
4.996V
3.366V
5.114V
27.886
36.3°C
115.15V
40W
2.656A
0.701A
0.687A
0.294A
39.998
79.804%
0
<6.0
46°C
0.901
12.304V
4.993V
3.363V
5.112V
50.12
37.32°C
115.15V
60W
4.107A
0.902A
0.884A
0.392A
60
83.119%
0
<6.0
46.24°C
0.936
12.303V
4.992V
3.361V
5.109V
72.183
38.26°C
115.15V
80W
5.554A
1.102A
1.08A
0.49A
79.964
85.385%
0
<6.0
47.78°C
0.947
12.302V
4.991V
3.36V
5.107V
93.652
39.24°C
115.15V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.206A
0.5A
0.49A
0.196A
19.999
72.32%
0
<6.0
42.18°C
0.492
12.305V
4.997V
3.365V
5.114V
27.654
36.89°C
230.37V
40W
2.656A
0.701A
0.687A
0.294A
39.997
79.844%
0
<6.0
41.02°C
0.625
12.304V
4.993V
3.362V
5.111V
50.094
37.22°C
230.37V
60W
4.106A
0.902A
0.884A
0.392A
59.996
83.564%
0
<6.0
43.67°C
0.712
12.303V
4.992V
3.361V
5.109V
71.795
38.14°C
230.37V
80W
5.553A
1.102A
1.08A
0.49A
79.949
86.048%
0
<6.0
47.06°C
0.744
12.302V
4.991V
3.36V
5.107V
92.918
39.33°C
230.37V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
14.1 mV
8.4 mV
5.7 mV
8.9 mV
Pass
20% Load
16.4 mV
9.4 mV
6.6 mV
10.4 mV
Pass
30% Load
18.0 mV
10.6 mV
7.5 mV
9.3 mV
Pass
40% Load
17.7 mV
8.9 mV
6.2 mV
9.3 mV
Pass
50% Load
21.2 mV
9.2 mV
5.7 mV
7.2 mV
Pass
60% Load
17.1 mV
9.4 mV
5.5 mV
7.1 mV
Pass
70% Load
20.3 mV
9.9 mV
5.9 mV
7.2 mV
Pass
80% Load
20.1 mV
15.0 mV
14.2 mV
7.5 mV
Pass
90% Load
20.6 mV
16.6 mV
15.2 mV
7.7 mV
Pass
100% Load
25.9 mV
18.0 mV
16.9 mV
10.6 mV
Pass
110% Load
29.1 mV
20.0 mV
18.3 mV
10.6 mV
Pass
Crossload 1
15.1 mV
11.4 mV
9.3 mV
10.0 mV
Pass
Crossload 2
20.5 mV
15.2 mV
7.1 mV
9.1 mV
Pass
Crossload 3
21.4 mV
8.5 mV
13.9 mV
9.3 mV
Pass
Crossload 4
22.3 mV
15.1 mV
15.1 mV
10.6 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.8 mV
8.2 mV
5.7 mV
9.6 mV
Pass
20% Load
16.9 mV
9.2 mV
6.7 mV
10.7 mV
Pass
30% Load
19.0 mV
10.6 mV
7.3 mV
9.4 mV
Pass
40% Load
18.2 mV
10.2 mV
8.1 mV
9.0 mV
Pass
50% Load
20.8 mV
9.6 mV
6.1 mV
7.4 mV
Pass
60% Load
17.8 mV
9.6 mV
6.0 mV
7.0 mV
Pass
70% Load
20.9 mV
10.1 mV
6.1 mV
7.1 mV
Pass
80% Load
19.2 mV
14.9 mV
14.0 mV
7.5 mV
Pass
90% Load
20.2 mV
16.5 mV
14.8 mV
8.7 mV
Pass
100% Load
26.8 mV
18.0 mV
16.7 mV
10.3 mV
Pass
110% Load
28.6 mV
19.9 mV
17.8 mV
10.9 mV
Pass
Crossload 1
16.0 mV
11.3 mV
9.3 mV
9.7 mV
Pass
Crossload 2
21.5 mV
14.7 mV
7.2 mV
9.3 mV
Pass
Crossload 3
20.2 mV
9.0 mV
12.7 mV
8.9 mV
Pass
Crossload 4
23.5 mV
14.6 mV
15.1 mV
10.9 mV
Pass
The results above are not used in the certification process
ZHONG YUAN POWER SFX-850GM
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted