CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Thermaltake Toughpower GF A3 750W (CE-Link)
Serial NumberPSTPD0750FNFAGULODVH00427
Lab IDTT75002527
Certification ID252527
  • Test Result Report ID: 24PS2527A
  • Certificate Issue Date: Aug 6, 2024
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

待機電源消耗

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 33.4 °C0 RPM · <6.0 dB(A) · 47.2 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 34.3 °C967 RPM · 24.3 dB(A) · 40.9 °Cfan starts (<6.0 → 24.3)
50%0 RPM · <6.0 dB(A) · 35.9 °C1305 RPM · 33.4 dB(A) · 42.3 °Cfan starts (<6.0 → 33.4)
100%1416 RPM · 35.5 dB(A) · 30.3 °C1792 RPM · 41.5 dB(A) · 45.7 °C+6.0 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 33.3 °C0 RPM · <6.0 dB(A) · 50.7 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 33.7 °C0 RPM · <6.0 dB(A) · 49.6 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 35.0 °C1100 RPM · 28.1 dB(A) · 42.3 °Cfan starts (<6.0 → 28.1)
100%1407 RPM · 35.5 dB(A) · 30.5 °C1791 RPM · 41.5 dB(A) · 45.2 °C+6.0 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Thermaltake Toughpower GF A3 750W (CE-Link)

Top side
Top side
Power specifications label
Power specifications label
Cybenetics 提供自願性認證方案:電源供應器方面有 ETA(效率)、LAMBDA(噪音)與 SAFE(安全與正確運作);散熱產品方面有 DELTA(機殼隔音)與 PHI(風扇風量與靜壓)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus