CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
ASRock Steel Legend SL-1000G / SL-1000GW
Serial Number
Lab IDAR10002542
Certification ID252542
  • Test Result Report ID: 24PS2542A
  • Certificate Issue Date: Aug 24, 2024
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 29.3 °C0 RPM · <6.0 dB(A) · 47.9 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 31.3 °C0 RPM · <6.0 dB(A) · 49.2 °Cfan off in both
50%484 RPM · <6.0 dB(A) · 29.2 °C505 RPM · <6.0 dB(A) · 42.4 °C<6.0 in both
100%1401 RPM · 34.6 dB(A) · 30.3 °C2005 RPM · 47.0 dB(A) · 45.8 °C+12.4 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 31.9 °C0 RPM · <6.0 dB(A) · 47.3 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 33.0 °C0 RPM · <6.0 dB(A) · 49.6 °Cfan off in both
50%491 RPM · <6.0 dB(A) · 29.7 °C1008 RPM · 24.3 dB(A) · 42.0 °C<6.0 → 24.3 dB(A)
100%1405 RPM · 34.7 dB(A) · 29.9 °C1933 RPM · 44.3 dB(A) · 45.5 °C+9.6 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

ASRock Steel Legend SL-1000G / SL-1000GW

Top side
Top side
Power specifications label
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern