Aristeidis Bitziopoulos, Certification Body General Manager
General Information
Main Specs
Product Identification Details
Brand
FSP Technology
Model
Hydro PTM Pro 1650W (ATXv3.1)
OEM
FSP
Serial Number
S3481000010
Product Specifications
Manufacturer
Rated Voltage (Vrms)
200-240
Rated Current (Arms)
10
Rated Frequency (Hz)
50-60
Rated Power (W)
1650
Operating Temperature (Continuous Full Load) (°C)
Type
ATX12V
Cable Design
Fully Modular
Warranty
Cybenetics
Dimensions (W x H x D)
Weight
Cooling
135mm Fluid Dynamic Bearing Fan (MGA13512XF-A25)
Semi-Passive Operation
✓ (selectable)
Cybenetics Testing Information
Lab ID
FS16502554
Date of receipt
Aug 20, 2024
Testing Date
Aug 29, 2024
Report Issued Date
Aug 30, 2024
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
16-22AWG
No
4+4 pin EPS12V (700mm)
2
2
16AWG
No
6+2 pin PCIe (650mm+150mm)
1
2
16-18AWG
No
6+2 pin PCIe (650mm)
2
2
16AWG
No
12+4 pin PCIe (700mm) (600W)
2
2
16-28AWG
No
SATA (500mm+155mm+155mm+155mm)
2
8
18AWG
No
SATA (500mm+150mm) / 4-pin Molex (+150mm+100mm)
2
4 / 4
18AWG
No
Protection Features(Non-accredited measurements)
Over Power Protection
✓
Over Current (+12V) Protection
✓
Over Temperature Protection
✓
Short Circuit Protection
✓
Surge Protection
✓
Inrush Current Protection
✓
Fan Failure Protection
✗
Power Specifications(Manufacturer)
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
20
20
137.5
3
0.3
Watts
120
1650
15
3.6
Total Max. Power (W)
1650
Parts Description
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
92.367%
Average Noise Output (>1450 Load Combinations)
29.85dBA
Average PF (>1450 Load Combinations)
0.980
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1349W
Non-Accredited
12V Ripple (Full Load)
29.01mV
5V Ripple (Full Load)
29.38mV
3.3V Ripple (Full Load)
27.29mV
5VSB Ripple (Full Load)
24.35mV
12V Load Regulation
0.63%
5V Load Regulation
0.51%
3.3V Load Regulation
0.65%
5VSB Load Regulation
2.76%
Inrush Current
45.930A
12V Transient Response (200%)
11.05V
5V Transient Response (200%)
4.966V
3.3V Transient Response (200%)
3.165V
5VSB Transient Response (200%)
4.827V
Hold-Up Time & Power Ok Signal
21.20ms
AC Loss to PWR_OK Hold Up Time
19.00ms
PWR_OK Inactive to DC Loss Delay
2.20ms
PSU Timings: T1 (20% / 100%)
52.0ms
44.0ms
PSU Timings: T3 (20% / 100%)
123.0ms
122.0ms
12V OCP (29.7°C / 43.9°C)
164.60A (119.71%), 12.012V
160.00A (116.36%), 12.053V
5V OCP (29.7°C / 43.9°C)
24.7A (123.50%), 5.048V
23A (115.00%), 5.053V
3.3V OCP (29.7°C / 43.9°C)
25A (125.00%), 3.316V
23.2A (116.00%), 3.321V
5VSB OCP (29.7°C / 43.9°C)
4.4A (146.67%), 4.99V
4.4A (146.67%), 4.989V
OPP (29.63°C / 43.11°C)
124.41%
120.17%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
21.2
AC Loss to PWR_OK Hold Up Time (ms)
19
PWR_OK Inactive to DC Loss Delay (ms)
2.2
待機電源消耗
Tables 230V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.87 V
229.79 V
227.70 V
229.93 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.419
1.417
1.340
1.420
1.490
PASS
Mains Voltage THD:
0.13 %
0.10 %
N/A
0.19 %
2.00 %
PASS
Real Power:
0.135 W
0.106 W
N/A
0.175 W
N/A
N/A
Apparent Power:
33.845 W
33.802 W
N/A
33.876 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input