CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
SAMA GT650W
Serial Number
Lab IDSM65002570
Certification ID252570
  • Test Result Report ID: 24PS2570A
  • Certificate Issue Date: Sep 17, 2024
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%970 RPM · 26.3 dB(A) · 30.4 °C992 RPM · 26.3 dB(A) · 40.2 °C+0.0 dB(A)
20%974 RPM · 26.4 dB(A) · 30.5 °C996 RPM · 26.8 dB(A) · 40.8 °C+0.4 dB(A)
50%980 RPM · 26.2 dB(A) · 30.6 °C1571 RPM · 39.3 dB(A) · 42.2 °C+13.1 dB(A)
100%1936 RPM · 43.5 dB(A) · 30.5 °C2044 RPM · 44.9 dB(A) · 45.2 °C+1.4 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%973 RPM · 26.4 dB(A) · 30.2 °C995 RPM · 26.4 dB(A) · 40.1 °C+0.0 dB(A)
20%976 RPM · 26.2 dB(A) · 30.4 °C998 RPM · 26.9 dB(A) · 41.0 °C+0.7 dB(A)
50%982 RPM · 26.0 dB(A) · 30.6 °C1636 RPM · 38.4 dB(A) · 42.5 °C+12.4 dB(A)
100%1927 RPM · 43.4 dB(A) · 30.1 °C2039 RPM · 44.8 dB(A) · 45.6 °C+1.4 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

SAMA GT650W

Top side
Top side
Power specifications label
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus