CYBENETICS LTD 塞浦路斯 尼科西亚 拉齐亚 2231 Syrou 6号
Thermaltake Toughpower SFX 750W (ATX v3.1)
序号PSSTP0750FNFAPE10DCH00316
Lab IDTT75002583
认证ID252583
  • 测试结果报告ID: 24PS2583A
  • 证书签发日期: Sep 27, 2024
115V230V
认证方案:ETA-EMI PSU
115V230V
认证方案:LAMBDA PSU
Aristeidis Bitziopoulos, 认证机构总经理

General Information

Test Equipment

DUT Information(Non-accredited measurements)

线材与接头(Non-accredited measurements)

保护功能

电源规格

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

保持时间 & PWR_OK 信号

待机功耗

Tables

Graphs

转换效率图表

噪声图

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 33.5 °C0 RPM · <6.0 dB(A) · 53.4 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 34.0 °C0 RPM · <6.0 dB(A) · 54.7 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 36.9 °C980 RPM · 13.6 dB(A) · 42.4 °Cfan starts (<6.0 → 13.6)
100%1831 RPM · 32.8 dB(A) · 32.5 °C2699 RPM · 43.7 dB(A) · 45.6 °C+10.9 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 32.0 °C0 RPM · <6.0 dB(A) · 50.4 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 32.5 °C0 RPM · <6.0 dB(A) · 51.4 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 38.3 °C911 RPM · 11.7 dB(A) · 42.5 °Cfan starts (<6.0 → 11.7)
100%1846 RPM · 33.3 dB(A) · 31.4 °C2649 RPM · 43.4 dB(A) · 45.6 °C+10.1 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

传导发射 EN 55032 & CISPR 32

Indicative Performance

高环温电源转换效率

5VSB效率

5VSB效率(ERP LOT 3/6与CEC)

Protection Features

Supplementary Tests (For Reference)

典型负载测试

轻载测试

纹波测量

Thermaltake Toughpower SFX 750W (ATX v3.1)

Top side
Top side
Power specifications label
Power specifications label
本测试报告中包含的所有数据和图表,任何个人在满足以下条件时均可使用:
› 应注明测试结果由 Cybenetics 提供
› 在任何情况下均应提供原始测试结果文档的链接
Cybenetics为电源开展自愿性认证项目——ETA针对效率、LAMBDA针对噪音、SAFE针对安全性与正确运行——同时也为散热产品提供认证,其中DELTA针对机箱隔音,PHI针对风扇风量与静压。THETA在ISO 17065与认可范围之外,对AMD AM5和Intel LGA1851平台上的散热器性能进行评级。
CYBENETICS LTD 塞浦路斯 尼科西亚 拉齐亚 2231 Syrou 6号