Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 24 pin (590mm)
1
1
16-22AWG
No
4+4 pin EPS12V (650mm)
2
2
18AWG
No
6+2 pin PCIe (650mm+100mm)
3
6
16AWG
No
12+4 pin PCIe (650mm) (600W)
1
1
16-26AWG
No
SATA (510mm+150mm+150mm+150mm)
3
12
18AWG
No
4-pin Molex (500mm+150mm+150mm+150mm)
1
4
18AWG
No
AC Power Cord (1400mm) - C13 coupler
1
1
17AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
PLATINUM
噪音評比
A-
Average Efficiency (>1450 load combinations)
89.128%
Average Noise Output (>1450 Load Combinations)
27.81dBA
Average PF (>1450 Load Combinations)
0.987
Efficiency With 10W (≤500W) or 2% (>500W) Load
66.286%
Standby Power Consumption
0.0365W
12V Ripple (Full Load)
25.84mV
5V Ripple (Full Load)
18.98mV
3.3V Ripple (Full Load)
15.37mV
5VSB Ripple (Full Load)
15.57mV
12V Load Regulation
1.37%
5V Load Regulation
0.26%
3.3V Load Regulation
0.48%
5VSB Load Regulation
1.54%
Inrush Current
36.960A
效率評比
PLATINUM
噪音評比
A-
Average Efficiency (>1450 load combinations)
91.249%
Average Noise Output (>1450 Load Combinations)
27.54dBA
Average PF (>1450 Load Combinations)
0.950
Efficiency With 10W (≤500W) or 2% (>500W) Load
67.232%
Standby Power Consumption
0.0707W
12V Ripple (Full Load)
25.05mV
5V Ripple (Full Load)
19.85mV
3.3V Ripple (Full Load)
14.69mV
5VSB Ripple (Full Load)
15.82mV
12V Load Regulation
1.33%
5V Load Regulation
0.32%
3.3V Load Regulation
0.51%
5VSB Load Regulation
1.62%
Inrush Current
67.520A
12V Transient Response (200%)
11.20V
5V Transient Response (200%)
4.898V
3.3V Transient Response (200%)
3.205V
5VSB Transient Response (200%)
4.913V
Hold-Up Time & Power Ok Signal
19.00ms
AC Loss to PWR_OK Hold Up Time
16.40ms
PWR_OK Inactive to DC Loss Delay
2.60ms
PSU Timings: T1 (20% / 100%)
105.0ms
86.0ms
PSU Timings: T3 (20% / 100%)
124.0ms
124.0ms
12V OCP (30.0°C / 42.6°C)
121.80A (146.22%), 11.880V
114.00A (136.85%), 11.935V
5V OCP (30.0°C / 42.6°C)
30A (150.00%), 4.954V
30.1A (150.50%), 4.967V
3.3V OCP (30.0°C / 42.6°C)
28A (140.00%), 3.302V
27.9A (139.50%), 3.306V
5VSB OCP (30.0°C / 42.6°C)
6.2A (206.67%), 4.892V
6.3A (210.00%), 4.886V
OPP (30.73°C / 42.85°C)
143.11%
131.31%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
19
AC Loss to PWR_OK Hold Up Time (ms)
16.4
PWR_OK Inactive to DC Loss Delay (ms)
2.6
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.08 V
115.04 V
113.85 V
115.12 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.13 %
0.08 %
N/A
0.21 %
2.00 %
PASS
Real Power:
0.037 W
-0.009 W
N/A
0.075 W
N/A
N/A
Apparent Power:
8.508 W
8.061 W
N/A
8.949 W
N/A
N/A
Power Factor:
0.007
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.01 V
230.93 V
227.70 V
231.08 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.071 W
0.031 W
N/A
0.124 W
N/A
N/A
Apparent Power:
26.847 W
26.269 W
N/A
27.400 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input