Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 24 pin (645mm)
1
1
16AWG
No
4+4 pin EPS12V (650mm)
1
1
16AWG
No
8 pin EPS12V (650mm)
1
1
16AWG
No
6+2 pin PCIe (550mm)
4
4
16-18AWG
No
12+4 pin PCIe (650mm) (600W)
1
1
16-28AWG
No
SATA (500mm+150mm+150mm+150mm)
3
12
18AWG
No
4-pin Molex (450mm+120mm+120mm+120mm)
1
4
18AWG
No
M/B USB Connector (800mm)
1
1
24AWG
No
4-pin PWM Fan Connector (400mm)
1
1
28AWG
No
AC Power Cord (1380mm) - C13 coupler
1
1
17AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
PLATINUM
噪音評比
A++
Average Efficiency (>1450 load combinations)
90.900%
Average Noise Output (>1450 Load Combinations)
6.00dBA
Average PF (>1450 Load Combinations)
0.995
Efficiency With 10W (≤500W) or 2% (>500W) Load
61.124%
Standby Power Consumption
0.0687W
12V Ripple (Full Load)
33.61mV
5V Ripple (Full Load)
19.69mV
3.3V Ripple (Full Load)
15.45mV
5VSB Ripple (Full Load)
9.82mV
12V Load Regulation
0.27%
5V Load Regulation
1.00%
3.3V Load Regulation
1.30%
5VSB Load Regulation
2.53%
Inrush Current
16.850A
效率評比
PLATINUM
噪音評比
A++
Average Efficiency (>1450 load combinations)
92.807%
Average Noise Output (>1450 Load Combinations)
6.00dBA
Average PF (>1450 Load Combinations)
0.976
Efficiency With 10W (≤500W) or 2% (>500W) Load
60.875%
Standby Power Consumption
0.1617W
12V Ripple (Full Load)
33.09mV
5V Ripple (Full Load)
21.19mV
3.3V Ripple (Full Load)
18.08mV
5VSB Ripple (Full Load)
11.29mV
12V Load Regulation
0.45%
5V Load Regulation
1.16%
3.3V Load Regulation
1.51%
5VSB Load Regulation
2.64%
Inrush Current
33.540A
12V Transient Response (200%)
11.49V
5V Transient Response (200%)
4.904V
3.3V Transient Response (200%)
3.206V
5VSB Transient Response (200%)
4.987V
Hold-Up Time & Power Ok Signal
26.80ms
AC Loss to PWR_OK Hold Up Time
16.80ms
PWR_OK Inactive to DC Loss Delay
10.00ms
PSU Timings: T1 (20% / 100%)
77.0ms
44.0ms
PSU Timings: T3 (20% / 100%)
125.0ms
126.0ms
12V OCP (29.2°C / 40.6°C)
88.40A (124.86%), 12.009V
87.80A (124.01%), 12.030V
5V OCP (29.2°C / 40.6°C)
25.1A (125.50%), 5.002V
24.5A (122.50%), 5.012V
3.3V OCP (29.2°C / 40.6°C)
25.5A (127.50%), 3.335V
24.8A (124.00%), 3.343V
5VSB OCP (29.2°C / 40.6°C)
4.6A (153.33%), 4.989V
4.6A (153.33%), 4.991V
OPP (28.51°C / 41.63°C)
125.13%
123.84%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
26.8
AC Loss to PWR_OK Hold Up Time (ms)
16.8
PWR_OK Inactive to DC Loss Delay (ms)
10
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.08 V
115.03 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.94 Hz
59.40 Hz
60.02 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.14 %
0.10 %
N/A
0.20 %
2.00 %
PASS
Real Power:
0.069 W
0.004 W
N/A
0.177 W
N/A
N/A
Apparent Power:
14.366 W
14.165 W
N/A
14.563 W
N/A
N/A
Power Factor:
0.010
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.02 V
230.92 V
227.70 V
231.09 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.27 %
2.00 %
PASS
Real Power:
0.162 W
0.119 W
N/A
0.236 W
N/A
N/A
Apparent Power:
47.760 W
47.330 W
N/A
48.194 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input