Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 24 pin (645mm)
1
1
16AWG
No
4+4 pin EPS12V (650mm)
1
1
16AWG
No
8 pin EPS12V (650mm)
1
1
16AWG
No
6+2 pin PCIe (550mm)
4
4
16-18AWG
No
12+4 pin PCIe (650mm) (600W)
1
1
16-28AWG
No
SATA (500mm+150mm+150mm+150mm)
3
12
18AWG
No
4-pin Molex (450mm+120mm+120mm+120mm)
1
4
18AWG
No
M/B USB Connector (800mm)
1
1
24AWG
No
4-pin PWM Fan Connector (400mm)
1
1
28AWG
No
AC Power Cord (1380mm) - C13 coupler
1
1
17AWG
-
Protection Features(Manufacturer)
Over Power Protection
✓
Over Current (+12V) Protection
✓
Over Temperature Protection
✓
Short Circuit Protection
✓
Surge Protection
✓
Inrush Current Protection
✓
Fan Failure Protection
-
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
20
20
70.8
3
0.3
Watts
120
850
15
3.6
Total Max. Power (W)
850
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
90.900%
Average Noise Output (>1450 Load Combinations)
6.00dBA
Average PF (>1450 Load Combinations)
0.995
Efficiency With 10W (≤500W) or 2% (>500W) Load
61.124%
Standby Power Consumption
0.0687W
Non-Accredited
12V Ripple (Full Load)
33.61mV
5V Ripple (Full Load)
19.69mV
3.3V Ripple (Full Load)
15.45mV
5VSB Ripple (Full Load)
9.82mV
12V Load Regulation
0.27%
5V Load Regulation
1.00%
3.3V Load Regulation
1.30%
5VSB Load Regulation
2.53%
Inrush Current
16.850A
Accredited
Average Efficiency (>1450 load combinations)
92.807%
Average Noise Output (>1450 Load Combinations)
6.00dBA
Average PF (>1450 Load Combinations)
0.976
Efficiency With 10W (≤500W) or 2% (>500W) Load
60.875%
Standby Power Consumption
0.1617W
Non-Accredited
12V Ripple (Full Load)
33.09mV
5V Ripple (Full Load)
21.19mV
3.3V Ripple (Full Load)
18.08mV
5VSB Ripple (Full Load)
11.29mV
12V Load Regulation
0.45%
5V Load Regulation
1.16%
3.3V Load Regulation
1.51%
5VSB Load Regulation
2.64%
Inrush Current
33.540A
12V Transient Response (200%)
11.49V
5V Transient Response (200%)
4.904V
3.3V Transient Response (200%)
3.206V
5VSB Transient Response (200%)
4.987V
Hold-Up Time & PWR_OK Signal
26.80ms
AC Loss to PWR_OK Hold Up Time
16.80ms
PWR_OK Inactive to DC Loss Delay
10.00ms
PSU Timings: T1 (20% / 100%)
77.0ms
44.0ms
PSU Timings: T3 (20% / 100%)
125.0ms
126.0ms
12V OCP (29.2°C / 40.6°C)
88.40A (124.86%), 12.009V
87.80A (124.01%), 12.030V
5V OCP (29.2°C / 40.6°C)
25.1A (125.50%), 5.002V
24.5A (122.50%), 5.012V
3.3V OCP (29.2°C / 40.6°C)
25.5A (127.50%), 3.335V
24.8A (124.00%), 3.343V
5VSB OCP (29.2°C / 40.6°C)
4.6A (153.33%), 4.989V
4.6A (153.33%), 4.991V
OPP (28.51°C / 41.63°C)
125.13%
123.84%
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
26.8
AC Loss to PWR_OK Hold Up Time (ms)
16.8
PWR_OK Inactive to DC Loss Delay (ms)
10
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.08 V
115.03 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.94 Hz
59.40 Hz
60.02 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.14 %
0.10 %
N/A
0.20 %
2.00 %
PASS
Real Power:
0.069 W
0.004 W
N/A
0.177 W
N/A
N/A
Apparent Power:
14.366 W
14.165 W
N/A
14.563 W
N/A
N/A
Power Factor:
0.010
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.02 V
230.92 V
227.70 V
231.09 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.27 %
2.00 %
PASS
Real Power:
0.162 W
0.119 W
N/A
0.236 W
N/A
N/A
Apparent Power:
47.760 W
47.330 W
N/A
48.194 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
NLO
✓
Fan Failure Protection
Passive
SIP
Surge: MOV Inrush: NTC & Bypass Relay
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
5.254A
1.983A
1.966A
0.985A
85.002
84.31%
42.17°C
0.98
12.068V
5.043V
3.357V
5.076V
100.835
40.22°C
114.82V
20%
11.524A
2.978A
2.953A
1.185A
169.933
89.66%
43.44°C
0.994
12.065V
5.037V
3.352V
5.065V
189.53
40.77°C
114.78V
30%
18.149A
3.477A
3.45A
1.385A
254.938
91.57%
43.86°C
0.997
12.062V
5.033V
3.348V
5.054V
278.406
41.32°C
114.79V
40%
24.783A
3.977A
3.947A
1.586A
340.022
92.343%
44.7°C
0.998
12.058V
5.028V
3.344V
5.043V
368.274
41.62°C
115.02V
50%
31.053A
4.977A
4.941A
1.789A
424.819
92.563%
45.93°C
0.998
12.054V
5.023V
3.34V
5.032V
458.961
42.13°C
114.76V
60%
37.307A
5.979A
5.937A
1.992A
509.364
92.34%
47.28°C
0.998
12.050V
5.018V
3.335V
5.021V
551.355
42.76°C
114.68V
70%
43.630A
6.984A
6.937A
2.196A
594.668
92.395%
49.09°C
0.998
12.046V
5.012V
3.33V
5.01V
643.609
43.17°C
114.69V
80%
49.959A
7.988A
7.937A
2.299A
679.503
92.18%
51.02°C
0.999
12.042V
5.007V
3.326V
5.001V
737.214
43.83°C
114.91V
90%
56.686A
8.495A
8.428A
2.404A
764.93
91.902%
53.63°C
0.998
12.039V
5.003V
3.322V
4.993V
832.306
44.4°C
115.09V
100%
63.151A
9.003A
8.95A
3.018A
849.746
91.5%
56.49°C
0.999
12.035V
4.998V
3.318V
4.971V
928.738
45.95°C
114.92V
110%
69.485A
10.014A
10.049A
3.022A
934.319
91.045%
60.08°C
0.999
12.032V
4.993V
3.313V
4.965V
1026.084
46.31°C
114.67V
CL1
0.115A
14.389A
14.272A
0A
121.296
84.837%
59.72°C
0.988
12.079V
5.018V
3.342V
5.095V
142.977
42.28°C
114.85V
CL2
0.115A
19.897A
0A
0A
101.34
83.425%
57.87°C
0.985
12.081V
5.023V
3.352V
5.099V
121.478
42.88°C
114.81V
CL3
0.114A
0A
19.692A
0A
67.382
78.791%
55.99°C
0.971
12.080V
5.039V
3.352V
5.099V
85.51
42.75°C
114.85V
CL4
70.559A
0A
0A
0A
849.504
92.052%
57.44°C
0.999
12.040V
5.024V
3.336V
5.05V
922.831
46.26°C
114.57V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
5.251A
1.982A
1.965A
0.985A
85.003
85.486%
44.93°C
0.879
12.074V
5.044V
3.358V
5.077V
99.439
40.15°C
229.82V
20%
11.520A
2.977A
2.952A
1.185A
169.936
90.873%
44.91°C
0.957
12.070V
5.039V
3.353V
5.066V
187.001
40.74°C
229.81V
30%
18.143A
3.476A
3.449A
1.385A
254.94
92.81%
45.11°C
0.979
12.065V
5.034V
3.349V
5.055V
274.666
41.23°C
229.8V
40%
24.777A
3.977A
3.947A
1.586A
340.024
93.68%
45.4°C
0.987
12.060V
5.029V
3.345V
5.044V
362.998
41.65°C
229.79V
50%
31.049A
4.977A
4.941A
1.788A
424.828
94.062%
45.71°C
0.991
12.056V
5.023V
3.34V
5.033V
451.516
42.06°C
229.78V
60%
37.304A
5.979A
5.937A
1.992A
509.363
94.324%
46.97°C
0.994
12.051V
5.018V
3.335V
5.022V
540.029
42.83°C
229.77V
70%
43.629A
6.983A
6.937A
2.196A
594.682
94.397%
47.84°C
0.995
12.047V
5.012V
3.33V
5.01V
629.993
43.08°C
229.75V
80%
49.958A
7.988A
7.937A
2.299A
679.515
94.39%
48.87°C
0.996
12.042V
5.007V
3.326V
5.002V
719.847
43.5°C
229.73V
90%
56.689A
8.495A
8.428A
2.404A
764.943
94.347%
49.6°C
0.997
12.038V
5.002V
3.322V
4.993V
810.789
44.5°C
229.72V
100%
63.155A
9.003A
8.951A
3.018A
849.759
94.227%
51.11°C
0.997
12.035V
4.998V
3.318V
4.971V
901.823
45.67°C
229.7V
110%
69.492A
10.015A
10.049A
3.022A
934.333
94.081%
52.51°C
0.998
12.031V
4.992V
3.313V
4.964V
993.062
46.98°C
229.69V
CL1
0.116A
14.391A
14.273A
0A
121.297
85.97%
49.79°C
0.932
12.077V
5.017V
3.342V
5.095V
141.102
42.21°C
229.82V
CL2
0.115A
19.899A
0A
0A
101.344
84.472%
49.56°C
0.91
12.079V
5.023V
3.352V
5.099V
119.965
42.33°C
229.83V
CL3
0.114A
0A
19.694A
0A
67.382
79.434%
47.71°C
0.85
12.077V
5.039V
3.351V
5.099V
84.845
41.93°C
229.84V
CL4
70.575A
0A
0A
0A
849.518
94.78%
49.82°C
0.998
12.038V
5.024V
3.336V
5.05V
896.341
44.56°C
229.71V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
1.231A
0.495A
0.491A
0.196A
19.998
64.675%
44.98°C
0.88
12.063V
5.047V
3.36V
5.097V
30.922
36.14°C
114.84V
40W
2.708A
0.693A
0.687A
0.294A
39.997
76.175%
44.12°C
0.941
12.068V
5.048V
3.361V
5.095V
52.505
37.94°C
114.84V
60W
4.187A
0.891A
0.884A
0.393A
59.997
81.78%
41.79°C
0.965
12.068V
5.047V
3.36V
5.092V
73.365
38.77°C
114.82V
80W
5.660A
1.09A
1.08A
0.491A
79.939
84.201%
41.06°C
0.978
12.068V
5.046V
3.359V
5.088V
94.944
39.48°C
114.81V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
1.229A
0.494A
0.49A
0.196A
20.007
64.316%
58.58°C
0.534
12.089V
5.056V
3.368V
5.102V
31.123
36.1°C
229.83V
40W
2.705A
0.693A
0.686A
0.294A
40.003
77.215%
55.12°C
0.714
12.086V
5.054V
3.366V
5.098V
51.804
37.06°C
229.83V
60W
4.182A
0.891A
0.883A
0.393A
60.002
81.778%
54.89°C
0.814
12.084V
5.052V
3.364V
5.094V
73.385
38.14°C
229.82V
80W
5.654A
1.089A
1.079A
0.491A
79.947
85.412%
54.1°C
0.867
12.082V
5.05V
3.363V
5.09V
93.634
39.14°C
229.82V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.7 mV
12.6 mV
11.7 mV
6.7 mV
Pass
20% Load
10.4 mV
12.9 mV
11.4 mV
6.6 mV
Pass
30% Load
11.5 mV
13.3 mV
12.2 mV
6.8 mV
Pass
40% Load
13.0 mV
14.2 mV
11.7 mV
7.1 mV
Pass
50% Load
14.3 mV
15.0 mV
13.3 mV
7.7 mV
Pass
60% Load
16.2 mV
14.1 mV
12.7 mV
7.3 mV
Pass
70% Load
18.4 mV
15.2 mV
14.5 mV
8.8 mV
Pass
80% Load
20.6 mV
16.9 mV
16.7 mV
8.7 mV
Pass
90% Load
22.7 mV
16.5 mV
15.4 mV
8.5 mV
Pass
100% Load
33.6 mV
19.7 mV
15.5 mV
9.8 mV
Pass
110% Load
37.1 mV
20.2 mV
16.3 mV
10.5 mV
Pass
Crossload 1
13.8 mV
20.2 mV
15.0 mV
22.3 mV
Pass
Crossload 2
11.4 mV
19.9 mV
13.3 mV
17.3 mV
Pass
Crossload 3
10.9 mV
12.0 mV
15.0 mV
17.2 mV
Pass
Crossload 4
34.3 mV
14.8 mV
13.9 mV
23.2 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.6 mV
15.6 mV
14.2 mV
12.9 mV
Pass
20% Load
12.1 mV
15.3 mV
14.8 mV
13.4 mV
Pass
30% Load
11.1 mV
14.3 mV
11.9 mV
6.9 mV
Pass
40% Load
12.7 mV
14.4 mV
12.8 mV
7.9 mV
Pass
50% Load
13.5 mV
13.3 mV
12.8 mV
7.0 mV
Pass
60% Load
15.8 mV
16.7 mV
13.2 mV
7.5 mV
Pass
70% Load
17.0 mV
15.0 mV
13.3 mV
8.1 mV
Pass
80% Load
18.8 mV
16.7 mV
15.3 mV
8.4 mV
Pass
90% Load
20.7 mV
16.0 mV
14.4 mV
8.2 mV
Pass
100% Load
33.1 mV
21.2 mV
18.1 mV
11.3 mV
Pass
110% Load
34.8 mV
21.6 mV
19.8 mV
11.1 mV
Pass
Crossload 1
16.4 mV
22.3 mV
18.1 mV
23.5 mV
Pass
Crossload 2
12.4 mV
21.7 mV
14.4 mV
19.2 mV
Pass
Crossload 3
10.9 mV
12.8 mV
15.1 mV
17.9 mV
Pass
Crossload 4
30.7 mV
15.8 mV
14.9 mV
22.4 mV
Pass
The results above are not used in the certification process
Cooler Master X Silent Edge Platinum 850
Top side
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern