Aristeidis Bitziopoulos, Certification Body General Manager
General Information
Main Specs
Product Identification Details
Brand
Super Flower
Model
Zillion 650W
OEM
Super Flower
Serial Number
Product Specifications
Manufacturer
Rated Voltage (Vrms)
200-240
Rated Current (Arms)
6
Rated Frequency (Hz)
50-60
Rated Power (W)
650
Operating Temperature (Continuous Full Load) (°C)
Type
ATX12V
Cable Design
Fixed cables
Warranty
Cybenetics
Dimensions (W x H x D)
Weight
Cooling
120mm Sleeve Bearing Fan (ZFH122512H)
Semi-Passive Operation
✗
Cybenetics Testing Information
Lab ID
SF65002612
Date of receipt
Oct 3, 2024
Testing Date
Oct 14, 2024
Report Issued Date
Oct 15, 2024
DUT Notes
The unit had voltage drop during +12V OCP testing under normal conditions and didn't shut down. Hold up time lower than 17ms.
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (510mm)
1
1
18AWG
No
8 pin EPS12V (605mm) / 4+4 pin EPS12V (+150mm)
2
1 / 1
18AWG
No
6+2 pin PCIe (525mm+140mm)
1
2
18AWG
No
6+2 pin PCIe (520mm)
1
1
18AWG
No
SATA (465mm+155mm+155mm) / 4-pin Molex (+150mm)
2
6 / 2
18AWG
No
Modular Cables
AC Power Cord (1370mm) - C13 coupler
1
1
18AWG
No
Protection Features(Non-accredited measurements)
Over Power Protection
✓
Over Current (+12V) Protection
✗
Over Temperature Protection
✓
Short Circuit Protection
✓
Surge Protection
✓
Inrush Current Protection
✓
Fan Failure Protection
✗
Power Specifications(Manufacturer)
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
18
18
54.1
3
0.3
Watts
100
649.2
15
3.6
Total Max. Power (W)
650
Parts Description
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
87.543%
Average Noise Output (>1450 Load Combinations)
34.76dBA
Average PF (>1450 Load Combinations)
0.946
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1175W
Non-Accredited
12V Ripple (Full Load)
48.20mV
5V Ripple (Full Load)
15.90mV
3.3V Ripple (Full Load)
23.70mV
5VSB Ripple (Full Load)
10.80mV
12V Load Regulation
1.03%
5V Load Regulation
2.37%
3.3V Load Regulation
4.42%
5VSB Load Regulation
5.59%
Inrush Current
63.150A
12V Transient Response (150%)
11.59V
5V Transient Response (150%)
4.869V
3.3V Transient Response (150%)
3.176V
5VSB Transient Response (150%)
5.012V
Hold-Up Time & Power Ok Signal
16.50ms
AC Loss to PWR_OK Hold Up Time
14.20ms
PWR_OK Inactive to DC Loss Delay
2.30ms
PSU Timings: T1 (20% / 100%)
117.0ms
114.0ms
PSU Timings: T3 (20% / 100%)
300.0ms
311.0ms
12V OCP (29.3°C / 44.4°C)
76.60A (141.59%), 11.575V* *Didn't shut down, Voltage drop (10.921V@77A)
72.60A (134.20%), 11.916V
5V OCP (29.3°C / 44.4°C)
26.5A (147.22%), 4.938V
26.6A (147.78%), 4.936V
3.3V OCP (29.3°C / 44.4°C)
25.7A (142.78%), 3.223V
26.2A (145.56%), 3.219V
5VSB OCP (29.3°C / 44.4°C)
3.9A (130.00%), 4.943V
3.8A (126.67%), 4.935V
OPP (30.84°C / 44.13°C)
136.86%
123.16%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
16.5
AC Loss to PWR_OK Hold Up Time (ms)
14.2
PWR_OK Inactive to DC Loss Delay (ms)
2.3
待機電源消耗
Tables 230V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.02 V
230.90 V
227.70 V
231.09 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.27 %
2.00 %
PASS
Real Power:
0.117 W
0.069 W
N/A
0.185 W
N/A
N/A
Apparent Power:
26.370 W
25.254 W
N/A
27.576 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input