Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (295mm)
1
1
16-20AWG
No
4+4 pin EPS12V (400mm)
1
1
18AWG
No
6+2 pin PCIe (400mm)
2
2
18AWG
No
12+2 pin PCIe (675mm) (600W)
1
1
16-24AWG
No
SATA (100mm+115mm+115mm+115mm)
1
4
18AWG
No
4-pin Molex (100mm+115mm+115mm+115mm)
1
4
18AWG
No
AC Power Cord (1400mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
PLATINUM
Lautstärkeklasse
Standard++
Average Efficiency (>1450 load combinations)
89.242%
Average Noise Output (>1450 Load Combinations)
33.92dBA
Average PF (>1450 Load Combinations)
0.980
Efficiency With 10W (≤500W) or 2% (>500W) Load
62.190%
Standby Power Consumption
0.0594W
12V Ripple (Full Load)
36.60mV
5V Ripple (Full Load)
19.10mV
3.3V Ripple (Full Load)
13.50mV
5VSB Ripple (Full Load)
11.20mV
12V Load Regulation
0.15%
5V Load Regulation
1.22%
3.3V Load Regulation
2.12%
5VSB Load Regulation
1.87%
Inrush Current
32.880A
Wirkungsgrad
PLATINUM
Lautstärkeklasse
Standard++
Average Efficiency (>1450 load combinations)
91.018%
Average Noise Output (>1450 Load Combinations)
33.88dBA
Average PF (>1450 Load Combinations)
0.951
Efficiency With 10W (≤500W) or 2% (>500W) Load
39.096%
Standby Power Consumption
0.0939W
12V Ripple (Full Load)
37.30mV
5V Ripple (Full Load)
19.00mV
3.3V Ripple (Full Load)
13.70mV
5VSB Ripple (Full Load)
11.10mV
12V Load Regulation
0.28%
5V Load Regulation
1.24%
3.3V Load Regulation
2.15%
5VSB Load Regulation
1.83%
Inrush Current
63.740A
12V Transient Response (200%)
11.61V
5V Transient Response (200%)
4.943V
3.3V Transient Response (200%)
3.251V
5VSB Transient Response (200%)
4.967V
Hold-Up Time & Power Ok Signal
20.00ms
AC Loss to PWR_OK Hold Up Time
17.00ms
PWR_OK Inactive to DC Loss Delay
3.00ms
PSU Timings: T1 (20% / 100%)
60.0ms
60.0ms
PSU Timings: T3 (20% / 100%)
114.0ms
114.0ms
12V OCP (29.6°C / 43.5°C)
66.40A (132.80%), 11.969V
64.00A (128.00%), 11.977V
5V OCP (29.6°C / 43.5°C)
30.4A (152.00%), 5.012V
30.3A (151.50%), 5.011V
3.3V OCP (29.6°C / 43.5°C)
30.9A (154.50%), 3.325V
30.8A (154.00%), 3.321V
5VSB OCP (29.6°C / 43.5°C)
4.1A (164.00%), 5.027V
4.1A (164.00%), 5.021V
OPP (27.53°C / 41.93°C)
130.55%
126.57%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
20
AC Loss to PWR_OK Hold Up Time (ms)
17
PWR_OK Inactive to DC Loss Delay (ms)
3
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.07 V
115.03 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.94 Hz
59.40 Hz
60.03 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.059 W
-0.009 W
N/A
0.101 W
N/A
N/A
Apparent Power:
7.171 W
6.889 W
N/A
7.467 W
N/A
N/A
Power Factor:
0.008
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.01 V
230.91 V
227.70 V
231.08 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.27 %
2.00 %
PASS
Real Power:
0.094 W
0.049 W
N/A
0.156 W
N/A
N/A
Apparent Power:
23.300 W
22.900 W
N/A
23.728 W
N/A
N/A
Power Factor:
0.005
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input