Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 24 pin (600mm)
1
1
16-22AWG
No
4+4 pin EPS12V (650mm)
2
2
16AWG
No
6+2 pin PCIe (675mm)
4
4
16-18AWG
No
6+2 pin PCIe (675mm+75mm)
2
4
16-18AWG
No
12+4 pin PCIe (710mm) (600W)
1
1
16-24AWG
No
SATA (450mm+100mm+100mm)
3
9
18AWG
No
4-pin Molex (450mm+100mm+100mm)
1
3
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A
Average Efficiency (>1450 load combinations)
90.106%
Average Noise Output (>1450 Load Combinations)
23.39dBA
Average PF (>1450 Load Combinations)
0.995
Efficiency With 10W (≤500W) or 2% (>500W) Load
65.665%
Standby Power Consumption
0.0753W
12V Ripple (Full Load)
24.75mV
5V Ripple (Full Load)
16.32mV
3.3V Ripple (Full Load)
14.43mV
5VSB Ripple (Full Load)
18.14mV
12V Load Regulation
0.71%
5V Load Regulation
0.66%
3.3V Load Regulation
1.21%
5VSB Load Regulation
2.41%
Inrush Current
46.880A
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A
Average Efficiency (>1450 load combinations)
92.090%
Average Noise Output (>1450 Load Combinations)
23.20dBA
Average PF (>1450 Load Combinations)
0.973
Efficiency With 10W (≤500W) or 2% (>500W) Load
67.765%
Standby Power Consumption
0.1283W
12V Ripple (Full Load)
28.98mV
5V Ripple (Full Load)
20.36mV
3.3V Ripple (Full Load)
20.70mV
5VSB Ripple (Full Load)
19.15mV
12V Load Regulation
0.64%
5V Load Regulation
0.60%
3.3V Load Regulation
1.06%
5VSB Load Regulation
2.35%
Inrush Current
81.170A
12V Transient Response (200%)
11.38V
5V Transient Response (200%)
4.934V
3.3V Transient Response (200%)
3.192V
5VSB Transient Response (200%)
4.865V
Hold-Up Time & Power Ok Signal
24.20ms
AC Loss to PWR_OK Hold Up Time
22.20ms
PWR_OK Inactive to DC Loss Delay
2.00ms
PSU Timings: T1 (20% / 100%)
48.0ms
51.0ms
PSU Timings: T3 (20% / 100%)
128.0ms
125.0ms
12V OCP (28.1°C / 43.0°C)
131.80A (121.70%), 12.032V
127.20A (117.45%), 12.052V
5V OCP (28.1°C / 43.0°C)
27.8A (111.20%), 5.019V
26.3A (105.20%), 5.024V
3.3V OCP (28.1°C / 43.0°C)
30A (120.00%), 3.314V
27.7A (110.80%), 3.325V
5VSB OCP (28.1°C / 43.0°C)
4.2A (140.00%), 4.982V
4.1A (136.67%), 4.983V
OPP (28.42°C / 43.36°C)
125.85%
123.21%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
24.2
AC Loss to PWR_OK Hold Up Time (ms)
22.2
PWR_OK Inactive to DC Loss Delay (ms)
2
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.06 V
115.03 V
113.85 V
115.10 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.075 W
0.053 W
N/A
0.109 W
N/A
N/A
Apparent Power:
10.077 W
9.969 W
N/A
10.177 W
N/A
N/A
Power Factor:
0.006
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.02 V
230.92 V
227.70 V
231.08 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.17 %
0.15 %
N/A
0.25 %
2.00 %
PASS
Real Power:
0.128 W
0.080 W
N/A
0.230 W
N/A
N/A
Apparent Power:
34.271 W
33.986 W
N/A
34.598 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input