| 115V | 230V | |
| Scheme: ETA-EMI PSU | ![]() |
![]() |
| 115V | 230V | |
![]() |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 34.7 °C | 0 RPM · <6.0 dB(A) · 51.5 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 41.6 °C | 0 RPM · <6.0 dB(A) · 53.4 °C | fan off in both |
| 50% | 473 RPM · 11.1 dB(A) · 30.3 °C | 957 RPM · 24.6 dB(A) · 42.2 °C | +13.5 dB(A) |
| 100% | 1229 RPM · 31.1 dB(A) · 30.8 °C | 1593 RPM · 39.1 dB(A) · 45.1 °C | +8.0 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 34.9 °C | 0 RPM · <6.0 dB(A) · 50.7 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 39.2 °C | 0 RPM · <6.0 dB(A) · 51.9 °C | fan off in both |
| 50% | 472 RPM · 11.1 dB(A) · 30.8 °C | 883 RPM · 23.3 dB(A) · 42.3 °C | +12.2 dB(A) |
| 100% | 0 RPM · <6.0 dB(A) · 30.8 °C | 1576 RPM · 38.6 dB(A) · 45.1 °C | fan starts (<6.0 → 38.6) |
Informational. Not part of the ETA or LAMBDA rating.