CYBENETICS LTD 塞浦路斯 尼科西亚 拉齐亚 2231 Syrou 6号
Corsair RM750e (ATX v3.1)
序号A8WZF4420003ER
Lab IDCR75002625
认证ID252625
  • 测试结果报告ID: 24PS2625A
  • 证书签发日期: Nov 2, 2024
115V230V
认证方案:ETA-EMI PSU
115V230V
认证方案:LAMBDA PSU
验证范围之外
Aristeidis Bitziopoulos, 认证机构总经理

General Information

Test Equipment

DUT Information(Non-accredited measurements)

线材与接头(Non-accredited measurements)

保护功能

电源规格

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

保持时间 & PWR_OK 信号

待机功耗

Tables

Graphs

转换效率图表

噪声图

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 33.9 °C0 RPM · <6.0 dB(A) · 46.5 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 35.5 °C0 RPM · <6.0 dB(A) · 47.9 °Cfan off in both
50%399 RPM · <6.0 dB(A) · 30.6 °C405 RPM · <6.0 dB(A) · 42.2 °C<6.0 in both
100%1297 RPM · 33.4 dB(A) · 30.3 °C1807 RPM · 42.8 dB(A) · 45.1 °C+9.4 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%343 RPM · <6.0 dB(A) · 29.4 °C0 RPM · <6.0 dB(A) · 46.0 °C<6.0 in both
20%344 RPM · <6.0 dB(A) · 29.4 °C0 RPM · <6.0 dB(A) · 46.7 °C<6.0 in both
50%396 RPM · <6.0 dB(A) · 29.5 °C399 RPM · <6.0 dB(A) · 37.2 °C<6.0 in both
100%1291 RPM · 33.4 dB(A) · 29.6 °C1807 RPM · 42.8 dB(A) · 45.1 °C+9.4 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

传导发射 EN 55032 & CISPR 32

Indicative Performance

高环温电源转换效率

5VSB效率

5VSB效率(ERP LOT 3/6与CEC)

Protection Features

Supplementary Tests (For Reference)

典型负载测试

轻载测试

纹波测量

Corsair RM750e (ATX v3.1)

Top side
Top side
Power specifications label
Power specifications label
本测试报告中包含的所有数据和图表,任何个人在满足以下条件时均可使用:
› 应注明测试结果由 Cybenetics 提供
› 在任何情况下均应提供原始测试结果文档的链接
Cybenetics为电源开展自愿性认证项目——ETA针对效率、LAMBDA针对噪音、SAFE针对安全性与正确运行——同时也为散热产品提供认证,其中DELTA针对机箱隔音,PHI针对风扇风量与静压。THETA在ISO 17065与认可范围之外,对AMD AM5和Intel LGA1851平台上的散热器性能进行评级。
CYBENETICS LTD 塞浦路斯 尼科西亚 拉齐亚 2231 Syrou 6号