| 115V | 230V | |
| Scheme: ETA-EMI PSU | ![]() |
![]() |
| 115V | 230V | |
![]() |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 39.0 °C | 0 RPM · <6.0 dB(A) · 46.8 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 39.5 °C | 0 RPM · <6.0 dB(A) · 49.4 °C | fan off in both |
| 50% | 400 RPM · <6.0 dB(A) · 30.1 °C | 406 RPM · <6.0 dB(A) · 42.3 °C | fan off in both |
| 100% | 1044 RPM · 25.8 dB(A) · 30.1 °C | 1187 RPM · 30.1 dB(A) · 45.5 °C | +4.3 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 32.3 °C | 0 RPM · <6.0 dB(A) · 44.7 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 31.0 °C | 0 RPM · <6.0 dB(A) · 46.0 °C | fan off in both |
| 50% | 396 RPM · <6.0 dB(A) · 30.5 °C | 406 RPM · <6.0 dB(A) · 42.5 °C | fan off in both |
| 100% | 1038 RPM · 25.6 dB(A) · 30.6 °C | 1144 RPM · 28.9 dB(A) · 45.6 °C | +3.3 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.