CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Cooler Master V SFX Gold 750 (ATX v3.1)
Serial NumberMPY7501SFHAGV3EEU1243500002
Lab IDCM75002656
Certification ID252656
  • Test Result Report ID: 24PS2656A
  • Certificate Issue Date: Nov 26, 2024
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%831 RPM · <6.0 dB(A) · 29.5 °C1136 RPM · 13.8 dB(A) · 40.0 °C<6.0 → 13.8 dB(A)
20%833 RPM · <6.0 dB(A) · 30.5 °C1208 RPM · 16.1 dB(A) · 40.6 °C<6.0 → 16.1 dB(A)
50%1081 RPM · 12.1 dB(A) · 31.6 °C1595 RPM · 25.5 dB(A) · 42.3 °C+13.4 dB(A)
100%1907 RPM · 30.8 dB(A) · 31.0 °C2448 RPM · 38.7 dB(A) · 45.0 °C+7.9 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%711 RPM · <6.0 dB(A) · 29.9 °C1210 RPM · 16.2 dB(A) · 40.0 °C<6.0 → 16.2 dB(A)
20%813 RPM · <6.0 dB(A) · 30.1 °C1233 RPM · 16.6 dB(A) · 40.5 °C<6.0 → 16.6 dB(A)
50%1022 RPM · 10.9 dB(A) · 30.6 °C1587 RPM · 25.1 dB(A) · 42.0 °C+14.2 dB(A)
100%1792 RPM · 29.1 dB(A) · 30.1 °C2407 RPM · 38.1 dB(A) · 45.0 °C+9.0 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Cooler Master V SFX Gold 750 (ATX v3.1)

Top side
Top side
Power specifications label
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus