Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (590mm)
1
1
16-22AWG
No
4+4 pin EPS12V (700mm)
2
2
16AWG
No
6+2 pin PCIe (550mm+150mm)
2
4
16-18AWG
No
12+4 pin PCIe (605mm) (600W)
1
1
16-24AWG
No
SATA (450mm+150mm+150mm)
3
9
18AWG
No
4-pin Molex (450mm+150mm+150mm)
1
3
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
Performance Summary
效率評比
PLATINUM
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
89.143%
Average Noise Output (>1450 Load Combinations)
33.14dBA
Average PF (>1450 Load Combinations)
0.982
Efficiency With 10W (≤500W) or 2% (>500W) Load
50.976%
Standby Power Consumption
0.0343W
12V Ripple (Full Load)
42.17mV
5V Ripple (Full Load)
28.25mV
3.3V Ripple (Full Load)
30.17mV
5VSB Ripple (Full Load)
39.43mV
12V Load Regulation
1.03%
5V Load Regulation
0.78%
3.3V Load Regulation
1.22%
5VSB Load Regulation
3.62%
Inrush Current
17.600A
效率評比
PLATINUM
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
91.272%
Average Noise Output (>1450 Load Combinations)
32.85dBA
Average PF (>1450 Load Combinations)
0.951
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0866W
12V Ripple (Full Load)
32.44mV
5V Ripple (Full Load)
20.69mV
3.3V Ripple (Full Load)
24.94mV
5VSB Ripple (Full Load)
36.92mV
12V Load Regulation
1.06%
5V Load Regulation
0.74%
3.3V Load Regulation
1.09%
5VSB Load Regulation
3.58%
Inrush Current
63.000A
12V Transient Response (200%)
11.17V
5V Transient Response (200%)
4.930V
3.3V Transient Response (200%)
3.196V
5VSB Transient Response (200%)
4.828V
Hold-Up Time & Power Ok Signal
14.10ms
AC Loss to PWR_OK Hold Up Time
11.30ms
PWR_OK Inactive to DC Loss Delay
2.80ms
PSU Timings: T1 (20% / 100%)
39.0ms
39.0ms
PSU Timings: T3 (20% / 100%)
112.0ms
112.0ms
12V OCP (30.1°C / 43.4°C)
129.00A (129.00%), 11.976V
123.60A (123.60%), 11.989V
5V OCP (30.1°C / 43.4°C)
27.6A (138.00%), 4.996V
27.6A (138.00%), 4.986V
3.3V OCP (30.1°C / 43.4°C)
27A (135.00%), 3.275V
27A (135.00%), 3.272V
5VSB OCP (30.1°C / 43.4°C)
4.9A (163.33%), 5.061V
4.7A (156.67%), 5.057V
OPP (30.98°C / 46.23°C)
120.85%
116.27%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
14.1
AC Loss to PWR_OK Hold Up Time (ms)
11.3
PWR_OK Inactive to DC Loss Delay (ms)
2.8
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.04 V
115.02 V
113.85 V
115.09 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.08 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.034 W
-0.013 W
N/A
0.072 W
N/A
N/A
Apparent Power:
3.716 W
3.596 W
N/A
3.832 W
N/A
N/A
Power Factor:
0.015
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.00 V
230.89 V
227.70 V
231.06 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.27 %
2.00 %
PASS
Real Power:
0.087 W
0.049 W
N/A
0.144 W
N/A
N/A
Apparent Power:
12.355 W
12.194 W
N/A
12.528 W
N/A
N/A
Power Factor:
0.005
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input