| 230V | |
| Scheme: ETA-EMI PSU | ![]() |
| 230V | |
![]() |
Scheme: LAMBDA PSU |

| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 745 RPM · 16.5 dB(A) · 30.5 °C | 760 RPM · 16.8 dB(A) · 40.0 °C | +0.3 dB(A) |
| 20% | 752 RPM · 16.8 dB(A) · 30.2 °C | 764 RPM · 16.9 dB(A) · 40.8 °C | +0.1 dB(A) |
| 50% | 763 RPM · 16.9 dB(A) · 30.6 °C | 888 RPM · 21.0 dB(A) · 42.2 °C | +4.1 dB(A) |
| 100% | 1408 RPM · 34.5 dB(A) · 30.5 °C | 1950 RPM · 44.0 dB(A) · 45.2 °C | +9.5 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.