This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
NLO
✓
Fan Failure Protection
✗
SIP
Surge: MOV Inrush: NTC & Bypass Relay
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
3.600A
1.985A
1.974A
1.002A
65.012
80.78%
974
29.6
40.22°C
0.841
12.059V
5.039V
3.343V
4.992V
80.481
44.65°C
230.09V
20%
8.224A
2.985A
2.974A
1.207A
129.968
86.371%
977
29.7
40.94°C
0.921
12.046V
5.027V
3.329V
4.973V
150.477
46.54°C
230.08V
30%
13.207A
3.49A
3.483A
1.413A
194.976
88.249%
979
29.7
41.39°C
0.949
12.033V
5.016V
3.317V
4.955V
220.94
48.49°C
230.08V
40%
18.208A
3.998A
3.995A
1.621A
260.065
88.906%
981
29.8
41.95°C
0.961
12.020V
5.004V
3.304V
4.937V
292.517
49.75°C
230.08V
50%
22.868A
5.01A
5.016A
1.831A
325.065
88.845%
991
30
42.31°C
0.97
12.006V
4.992V
3.29V
4.917V
365.878
52.18°C
230.07V
60%
27.507A
6.028A
6.046A
2.001A
389.474
88.414%
1030
31.3
42.84°C
0.973
11.992V
4.979V
3.275V
4.898V
440.512
53.93°C
230.06V
70%
32.219A
7.052A
7.087A
2.256A
454.995
87.788%
1211
36.1
43.2°C
0.977
11.977V
4.965V
3.26V
4.876V
518.289
55.14°C
230.05V
80%
36.943A
8.081A
8.136A
2.368A
519.802
87.046%
1417
40.8
43.83°C
0.98
11.962V
4.951V
3.245V
4.858V
597.161
57.09°C
230.04V
90%
42.080A
8.607A
8.665A
2.479A
585.215
86.399%
1551
42.8
44.01°C
0.983
11.947V
4.939V
3.231V
4.841V
677.341
58.9°C
230.03V
100%
46.966A
9.137A
9.234A
3.121A
650.036
85.525%
1686
44.7
45.75°C
0.985
11.930V
4.926V
3.216V
4.807V
760.05
61.47°C
230.03V
110%
51.731A
10.181A
10.403A
3.131A
714.657
84.601%
1795
46.4
46.61°C
0.987
11.914V
4.911V
3.201V
4.791V
844.737
64.73°C
230.02V
CL1
0.116A
12.033A
12.02A
0A
101.314
74.194%
1051
31.7
41.87°C
0.912
12.043V
5.003V
3.303V
4.988V
136.558
54.69°C
230.09V
CL2
0.116A
14.95A
0A
0A
76.409
74.223%
1000
30.4
41°C
0.883
12.058V
5.017V
3.335V
5.009V
102.942
51.2°C
230.09V
CL3
0.116A
0A
14.923A
0A
50.898
68.533%
973
29.5
41.27°C
0.824
12.052V
5.032V
3.317V
5.005V
74.268
48.83°C
230.1V
CL4
54.408A
0A
0A
0.001A
649.821
86.629%
1603
43.4
45.58°C
0.985
11.944V
4.961V
3.255V
4.925V
750.126
58.16°C
230.03V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.232A
0.495A
0.492A
0.199A
20.01
66.491%
963
29.3
36.36°C
0.589
12.067V
5.05V
3.356V
5.026V
30.093
40.69°C
230.1V
40W
2.710A
0.694A
0.689A
0.299A
40.007
76.356%
969
29.4
37.87°C
0.751
12.064V
5.047V
3.352V
5.019V
52.396
42.14°C
230.1V
60W
4.190A
0.893A
0.887A
0.399A
60.006
81.361%
970
29.4
38.55°C
0.823
12.061V
5.044V
3.349V
5.013V
73.754
42.21°C
230.1V
80W
5.668A
1.092A
1.085A
0.5A
79.971
84.134%
971
29.4
39.12°C
0.871
12.057V
5.04V
3.345V
5.006V
95.053
43.17°C
230.1V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
10.38mV
7.70mV
4.48mV
10.03mV
Pass
20% Load
11.09mV
7.45mV
4.63mV
10.54mV
Pass
30% Load
12.88mV
7.70mV
5.14mV
35.87mV
Pass
40% Load
13.53mV
7.65mV
4.93mV
39.28mV
Pass
50% Load
14.35mV
7.60mV
5.09mV
40.81mV
Pass
60% Load
16.49mV
8.16mV
6.00mV
41.47mV
Pass
70% Load
20.51mV
8.21mV
5.80mV
35.20mV
Pass
80% Load
20.35mV
8.73mV
14.95mV
31.33mV
Pass
90% Load
23.97mV
9.44mV
15.41mV
22.62mV
Pass
100% Load
40.58mV
11.38mV
16.86mV
14.42mV
Pass
110% Load
47.10mV
12.02mV
18.60mV
15.94mV
Pass
Crossload1
31.25mV
12.83mV
31.54mV
10.60mV
Pass
Crossload2
35.62mV
35.04mV
10.02mV
8.56mV
Pass
Crossload3
27.68mV
10.25mV
31.84mV
9.43mV
Pass
Crossload4
45.53mV
14.36mV
11.69mV
15.42mV
Pass
The results above are not used in the certification process
1st Player ACK Bronze 650W (ATX v3.1)
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted