CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Segotep PM650W (SG-650P)
Serial NumberSAQN2B403000987
Lab IDST65002755
Certification ID252755
  • Test Result Report ID: 25PS2755A
  • Certificate Issue Date: Feb 28, 2025
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

待機電源消耗

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%793 RPM · 18.2 dB(A) · 30.0 °C827 RPM · 18.7 dB(A) · 40.1 °C+0.5 dB(A)
20%800 RPM · 18.3 dB(A) · 30.6 °C843 RPM · 19.2 dB(A) · 40.9 °C+0.9 dB(A)
50%809 RPM · 17.9 dB(A) · 30.8 °C1407 RPM · 34.4 dB(A) · 42.4 °C+16.5 dB(A)
100%1485 RPM · 35.8 dB(A) · 30.9 °C1511 RPM · 36.6 dB(A) · 45.9 °C+0.8 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%794 RPM · 18.2 dB(A) · 30.6 °C1317 RPM · 32.4 dB(A) · 40.4 °C+14.2 dB(A)
20%800 RPM · 18.3 dB(A) · 30.2 °C1391 RPM · 33.8 dB(A) · 40.7 °C+15.5 dB(A)
50%975 RPM · 23.1 dB(A) · 30.6 °C1497 RPM · 36.0 dB(A) · 42.5 °C+12.9 dB(A)
100%1483 RPM · 35.7 dB(A) · 30.4 °C1511 RPM · 36.6 dB(A) · 45.9 °C+0.9 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Segotep PM650W (SG-650P)

Top side
Top side
Power specifications label
Power specifications label
PSU Open
PSU Open
Failed Cable
Failed Cable
Cybenetics 提供自願性認證方案:電源供應器方面有 ETA(效率)、LAMBDA(噪音)與 SAFE(安全與正確運作);散熱產品方面有 DELTA(機殼隔音)與 PHI(風扇風量與靜壓)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus