CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Seasonic Prime PX-2200 ATX3
Serial Number-
Lab IDSS22002782
Certification ID252782
  • Test Result Report ID: 25PS2782A
  • Certificate Issue Date: Apr 7, 2025
230V
Scheme: ETA-EMI PSU
230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary 230V

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables 230V

Graphs 230V

Efficiency Graph

230V

Noise Graph

230V

Noise under high ambient temperature (indicative)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 30.9 °C0 RPM · <6.0 dB(A) · 41.4 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 31.6 °C0 RPM · <6.0 dB(A) · 42.4 °Cfan off in both
50%578 RPM · 12.1 dB(A) · 30.1 °C583 RPM · 12.3 dB(A) · 42.3 °C+0.2 dB(A)
100%1700 RPM · 43.6 dB(A) · 30.2 °C2381 RPM · 53.1 dB(A) · 45.8 °C+9.5 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC) 230V

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests 230V

Light Load Tests 230V

Ripple Measurements 230V

Seasonic Prime PX-2200 ATX3

Top side
Top side
Power specifications label
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus