The device's Leakage current (3.72mA) exceeds the limit (3.5mA). The +12V OCP triggering points are misconfigured.
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
线材与接头(Non-accredited measurements)
模组化线材
描述
线材数量
总连接器数量
Gauge
In Cable Capacitors
ATX 接头 24 pin (600mm)
1
1
16-18AWG
否
4+4 pin EPS 12V 接头 (600mm)
4
4
16AWG
否
6+2pin PCIe接头 (650mm+150mm)
2
4
16-18AWG
否
6+2pin PCIe接头 (600mm)
3
3
16AWG
否
12+4 pin PCIe (600mm) (600W)
4
4
16-24AWG
否
SATA接头 (550mm+105mm+105mm+105mm)
3
12
18AWG
否
4-pin Molex (550mm+105mm+105mm+105mm)
1
4
18AWG
否
Protection Features(Manufacturer)
Over Power Protection
?
Over Current (+12V) Protection
?
Over Temperature Protection
✓
Short Circuit Protection
✓
Surge Protection
✓
Inrush Current Protection
✓
Fan Failure Protection
✗
电源规范
组
3.3V
5V
12V
5VSB
-12V
最大功率
安培
22
22
137.5
3
0.3
瓦
120
1650
15
6
最大总功率 (W)
2500
Test Results
Temperature & Compliance Info
温度范围 (°C /°F)
30-32 / 86-89.6
符合ErP Lot3/6规范
✓
符合(EU) No 617/2013规范
✓
ALPM (Alternative Low Power Mode) compatible
✓
Performance Summary 115V
Accredited
平均效率 (>1450 load combinations)
89.954%
Average Noise Output (>1450 Load Combinations)
33.41dBA
PF平均值 (>1450 Load Combinations)
0.991
Efficiency With 10W (≤500W) or 2% (>500W) Load
66.696%
待机功率耗损
0.1106W
Non-Accredited
12V Ripple (Full Load)
33.32mV
5V Ripple (Full Load)
15.22mV
3.3V Ripple (Full Load)
16.51mV
5VSB Ripple (Full Load)
13.22mV
12V Load Regulation
1.27%
5V Load Regulation
1.21%
3.3V Load Regulation
1.60%
5VSB Load Regulation
2.74%
Inrush Current
32.510A
保持时间 & PG信号
Hold-Up Time (ms)
18.6
AC Loss to PWR_OK Hold Up Time (ms)
16.3
PWR_OK Inactive to DC Loss Delay (ms)
2.3
待机电源
Tables 115V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.07 V
115.03 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.14 %
0.10 %
N/A
0.20 %
2.00 %
PASS
Real Power:
0.111 W
0.085 W
N/A
0.137 W
N/A
N/A
Apparent Power:
9.943 W
9.391 W
N/A
10.516 W
N/A
N/A
Power Factor:
0.012
N/A
N/A
N/A
N/A
N/A
Graphs 115V
转换效率图表
115V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
115V
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯