CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Cooler Master MWE GOLD 850 V3 Non-modular
Serial NumberMPE8506ACAGBEU2251600001
Lab IDCM85002825
Certification ID252825
  • Test Result Report ID: 25PS2825A
  • Certificate Issue Date: Jun 4, 2025
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%824 RPM · 18.0 dB(A) · 30.9 °C1405 RPM · 32.7 dB(A) · 40.2 °C+14.7 dB(A)
20%948 RPM · 20.3 dB(A) · 30.5 °C1715 RPM · 37.9 dB(A) · 40.7 °C+17.6 dB(A)
50%1099 RPM · 24.8 dB(A) · 30.2 °C2026 RPM · 43.4 dB(A) · 42.1 °C+18.6 dB(A)
100%1899 RPM · 41.3 dB(A) · 30.9 °C2366 RPM · 46.6 dB(A) · 45.9 °C+5.3 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%792 RPM · 15.2 dB(A) · 30.1 °C1422 RPM · 32.9 dB(A) · 40.5 °C+17.7 dB(A)
20%794 RPM · 15.1 dB(A) · 30.1 °C1452 RPM · 34.8 dB(A) · 40.5 °C+19.7 dB(A)
50%800 RPM · 15.4 dB(A) · 30.5 °C1868 RPM · 40.9 dB(A) · 42.4 °C+25.5 dB(A)
100%1696 RPM · 37.5 dB(A) · 30.8 °C2368 RPM · 46.6 dB(A) · 45.0 °C+9.1 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Cooler Master MWE GOLD 850 V3 Non-modular

Top side
Top side
Power specifications label
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus