61.80A (134.93%), 11.867V *Voltage Drop (11.319V @62.8A), High Ripple (>200mV)
60.80A (132.75%), 11.938V *High Ripple (>200mV)
5V OCP (26.6°C / 41.3°C)
21A (116.67%), 5.018V
20.6A (114.44%), 5.018V
3.3V OCP (26.6°C / 41.3°C)
23.6A (131.11%), 3.32V
22.7A (126.11%), 3.323V
5VSB OCP (26.6°C / 41.3°C)
5.5A (220.00%), 4.82V
5.3A (212.00%), 4.857V
OPP (27.04°C / 41.30°C)
121.92%
127.38%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
15.2
AC Loss to PWR_OK Hold Up Time (ms)
13.8
PWR_OK Inactive to DC Loss Delay (ms)
1.4
Vampire Power
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.08 V
115.04 V
113.85 V
115.13 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.10 %
N/A
0.17 %
2.00 %
PASS
Real Power:
0.053 W
0.002 W
N/A
0.086 W
N/A
N/A
Apparent Power:
8.634 W
7.900 W
N/A
9.265 W
N/A
N/A
Power Factor:
0.008
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.03 V
230.91 V
227.70 V
231.10 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.29 %
2.00 %
PASS
Real Power:
0.143 W
0.094 W
N/A
0.212 W
N/A
N/A
Apparent Power:
27.206 W
26.154 W
N/A
28.192 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
UVP (Full Load @ 90V)
✓
UVP (No Damage @ 80V)
✓
Conducted Emissions EN55032 & CISPR 32
✓
NLO
✓
Fan Failure Protection
✗
SIP
Surge: MOV Inrush: NTC
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
2.776A
1.987A
1.965A
0.984A
54.999
78.951%
1790
37.6
40.48°C
0.977
12.035V
5.032V
3.358V
5.083V
69.664
41.48°C
114.81V
20%
6.571A
2.99A
2.96A
1.186A
109.929
84.604%
1805
37.8
40.7°C
0.988
12.026V
5.017V
3.344V
5.06V
129.934
41.58°C
114.79V
30%
10.723A
3.496A
3.465A
1.39A
164.921
86.071%
1834
38.2
41.4°C
0.992
12.018V
5.005V
3.333V
5.037V
191.611
42.63°C
114.78V
40%
14.889A
4.005A
3.974A
1.596A
220
86.592%
1838
38.2
41.76°C
0.995
12.009V
4.994V
3.321V
5.015V
254.065
42.7°C
114.75V
50%
18.710A
5.02A
4.989A
1.804A
274.996
86.352%
1842
38.3
42.25°C
0.996
11.999V
4.98V
3.307V
4.989V
318.465
43.45°C
114.74V
60%
22.534A
6.043A
6.013A
2A
329.913
85.912%
1846
38.3
42.85°C
0.996
11.990V
4.965V
3.293V
4.965V
384.016
43.81°C
114.72V
70%
26.369A
7.071A
7.046A
2.228A
384.978
85.106%
1848
38.3
43.27°C
0.997
11.979V
4.95V
3.279V
4.937V
452.352
44.06°C
114.7V
80%
30.206A
8.103A
8.086A
2.34A
439.398
84.181%
1853
38.4
43.96°C
0.998
11.968V
4.936V
3.265V
4.916V
521.968
44.58°C
114.67V
90%
34.454A
8.629A
8.609A
2.452A
494.435
83.214%
1855
38.4
45°C
0.998
11.956V
4.924V
3.252V
4.895V
594.172
45.02°C
114.65V
100%
38.710A
9.159A
9.165A
2.565A
549.543
81.959%
1857
38.4
45.83°C
0.998
11.944V
4.913V
3.24V
4.874V
670.512
46.35°C
114.63V
110%
42.619A
10.207A
10.324A
2.574A
604.562
80.408%
1860
38.4
46.51°C
0.998
11.938V
4.898V
3.225V
4.856V
751.876
47.19°C
114.6V
CL1
0.115A
12.089A
11.993A
0A
101.285
77.005%
1839
38.3
41.8°C
0.988
12.026V
4.98V
3.31V
5.086V
131.532
43.54°C
114.8V
CL2
0.115A
18.022A
0A
0A
91.358
76.539%
1833
38.3
41.45°C
0.989
12.032V
4.992V
3.322V
5.104V
119.363
44.07°C
114.79V
CL3
0.115A
0A
17.815A
0A
60.778
69.998%
1824
38.1
41.45°C
0.984
12.033V
5.004V
3.334V
5.103V
86.828
43.72°C
114.81V
CL4
46.004A
0A
0A
0.001A
549.486
83.542%
1857
38.4
45.33°C
0.998
11.944V
4.962V
3.286V
5.034V
657.736
48.37°C
114.64V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
2.776A
1.988A
1.966A
0.984A
55.001
80.374%
1826
38.1
40.45°C
0.817
12.034V
5.03V
3.358V
5.082V
68.433
42.11°C
229.8V
20%
6.572A
2.991A
2.961A
1.186A
109.932
86.219%
1831
38.2
40.77°C
0.926
12.026V
5.015V
3.344V
5.059V
127.502
42.24°C
229.8V
30%
10.724A
3.498A
3.466A
1.39A
164.925
87.806%
1839
38.3
41.02°C
0.958
12.017V
5.003V
3.332V
5.037V
187.83
42.88°C
229.79V
40%
14.891A
4.007A
3.975A
1.596A
220.006
88.436%
1844
38.3
41.58°C
0.973
12.008V
4.991V
3.321V
5.014V
248.776
44.61°C
229.78V
50%
18.711A
5.023A
4.99A
1.804A
275.001
88.296%
1848
38.3
42.48°C
0.98
11.999V
4.977V
3.307V
4.989V
311.454
45.49°C
229.77V
60%
22.536A
6.046A
6.013A
2A
329.921
87.965%
1850
38.3
42.83°C
0.984
11.988V
4.962V
3.293V
4.964V
375.058
46.83°C
229.76V
70%
26.372A
7.074A
7.046A
2.229A
384.998
87.33%
1855
38.4
43.3°C
0.988
11.978V
4.949V
3.279V
4.936V
440.859
48.32°C
229.76V
80%
30.215A
8.106A
8.088A
2.341A
439.483
86.636%
1856
38.3
43.86°C
0.99
11.968V
4.934V
3.264V
4.914V
507.282
48.88°C
229.75V
90%
34.456A
8.632A
8.608A
2.451A
494.504
86.008%
1857
38.4
44.3°C
0.991
11.958V
4.923V
3.253V
4.896V
574.955
49.35°C
229.73V
100%
38.704A
9.159A
9.166A
2.564A
549.573
85.231%
1861
38.5
45.65°C
0.991
11.946V
4.913V
3.24V
4.876V
644.807
51.85°C
229.72V
110%
42.631A
10.205A
10.324A
2.574A
604.572
84.166%
1864
38.6
46.99°C
0.993
11.934V
4.899V
3.225V
4.857V
718.314
54.16°C
229.71V
CL1
0.115A
12.089A
11.995A
0A
101.285
78.631%
1838
38.2
41.67°C
0.928
12.027V
4.98V
3.309V
5.087V
128.811
42.75°C
229.8V
CL2
0.115A
18.02A
0A
0A
91.36
77.959%
1833
38.3
41.32°C
0.917
12.032V
4.993V
3.322V
5.104V
117.191
41.38°C
229.8V
CL3
0.115A
0A
17.818A
0A
60.778
71.3%
1813
37.9
40.11°C
0.866
12.034V
5.003V
3.333V
5.103V
85.242
40.49°C
229.8V
CL4
46.008A
0A
0A
0.001A
549.503
86.696%
1857
38.4
45.6°C
0.99
11.943V
4.961V
3.285V
5.035V
633.831
49.11°C
229.73V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.233A
0.496A
0.49A
0.195A
19.997
66.22%
1471
31.9
36.49°C
0.915
12.041V
5.045V
3.371V
5.133V
30.198
36.82°C
114.81V
40W
2.716A
0.694A
0.686A
0.293A
39.998
76.788%
1564
33.7
37.27°C
0.959
12.038V
5.041V
3.367V
5.123V
52.089
37.57°C
114.81V
60W
4.198A
0.893A
0.883A
0.391A
59.998
80.776%
1675
35.9
38.2°C
0.979
12.034V
5.037V
3.363V
5.114V
74.262
38.56°C
114.83V
80W
5.678A
1.093A
1.081A
0.49A
79.938
83.628%
1733
36.6
39.03°C
0.986
12.031V
5.033V
3.358V
5.105V
95.588
39.55°C
114.8V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.234A
0.496A
0.49A
0.195A
19.999
66.382%
1407
31
36.76°C
0.565
12.041V
5.041V
3.37V
5.132V
30.128
36.9°C
229.82V
40W
2.716A
0.695A
0.686A
0.293A
39.999
77.985%
1609
34.6
37.46°C
0.744
12.037V
5.038V
3.366V
5.123V
51.294
38.36°C
229.82V
60W
4.199A
0.894A
0.883A
0.391A
59.999
82.51%
1686
36.1
38.6°C
0.831
12.034V
5.034V
3.362V
5.113V
72.715
39.19°C
229.81V
80W
5.678A
1.093A
1.081A
0.49A
79.941
84.805%
1767
37.1
39.19°C
0.884
12.030V
5.029V
3.358V
5.104V
94.263
39.82°C
229.81V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
19.59mV
16.99mV
17.19mV
16.32mV
Pass
20% Load
18.87mV
17.25mV
17.03mV
16.06mV
Pass
30% Load
19.23mV
17.25mV
17.91mV
16.52mV
Pass
40% Load
19.90mV
17.40mV
18.57mV
16.78mV
Pass
50% Load
20.97mV
16.53mV
18.21mV
16.52mV
Pass
60% Load
27.01mV
18.94mV
20.52mV
19.19mV
Pass
70% Load
32.02mV
18.94mV
22.16mV
20.27mV
Pass
80% Load
33.86mV
21.56mV
27.96mV
21.76mV
Pass
90% Load
34.17mV
22.99mV
28.68mV
23.04mV
Pass
100% Load
34.86mV
21.53mV
26.43mV
22.76mV
Pass
110% Load
37.82mV
22.28mV
26.33mV
24.29mV
Pass
Crossload1
19.13mV
21.49mV
27.13mV
11.79mV
Pass
Crossload2
23.37mV
32.90mV
24.98mV
12.47mV
Pass
Crossload3
22.40mV
20.02mV
30.37mV
14.26mV
Pass
Crossload4
35.23mV
16.68mV
17.57mV
16.91mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
19.64mV
18.02mV
16.93mV
16.26mV
Pass
20% Load
22.35mV
19.40mV
20.11mV
17.50mV
Pass
30% Load
22.76mV
20.63mV
20.37mV
17.91mV
Pass
40% Load
72.93mV
29.87mV
21.60mV
18.99mV
Pass
50% Load
24.04mV
19.86mV
21.45mV
18.32mV
Pass
60% Load
27.05mV
20.07mV
22.37mV
19.39mV
Pass
70% Load
34.78mV
21.76mV
24.52mV
21.34mV
Pass
80% Load
34.42mV
23.09mV
28.88mV
22.73mV
Pass
90% Load
35.39mV
22.84mV
28.22mV
23.60mV
Pass
100% Load
35.60mV
22.47mV
25.03mV
24.22mV
Pass
110% Load
39.17mV
22.25mV
27.41mV
25.36mV
Pass
Crossload1
21.02mV
22.45mV
27.50mV
13.17mV
Pass
Crossload2
23.17mV
32.44mV
24.06mV
14.21mV
Pass
Crossload3
23.78mV
21.56mV
31.14mV
15.09mV
Pass
Crossload4
31.52mV
17.60mV
17.51mV
18.30mV
Pass
The results above are not used in the certification process
Galax Omega 550W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted