CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
SAMA P1200 (China: XP1200)
Serial Number-
Lab IDSM12002928
Certification ID252928
  • Test Result Report ID: 25PS2928A
  • Certificate Issue Date: Aug 12, 2025
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 37.9 °C0 RPM · <6.0 dB(A) · 53.2 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 40.6 °C0 RPM · <6.0 dB(A) · 55.2 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 49.6 °C369 RPM · <6.0 dB(A) · 42.0 °Cfan off in both
100%982 RPM · 26.4 dB(A) · 30.3 °C1616 RPM · 41.4 dB(A) · 45.9 °C+15.0 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 31.4 °C0 RPM · <6.0 dB(A) · 49.8 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 37.3 °C0 RPM · <6.0 dB(A) · 51.8 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 42.1 °C360 RPM · <6.0 dB(A) · 42.2 °Cfan off in both
100%1141 RPM · 31.2 dB(A) · 30.2 °C1569 RPM · 41.0 dB(A) · 45.7 °C+9.8 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

SAMA P1200 (China: XP1200)

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus