Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (580mm)
1
1
16-18AWG
No
4+4 pin EPS12V (700mm)
1
1
16AWG
No
6+2 pin PCIe (600mm+120mm)
2
4
18AWG
No
SATA (450mm+120mm+120mm)
2
6
18AWG
No
SATA (450mm+120mm)
1
2
18AWG
No
4 pin Molex (400mm+120mm+120mm)
1
3
18AWG
No
AC Power Cord (1700mm) - C13 coupler
1
1
18AWG
-
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
24
24
54
3
0.5
Watts
130
648
15
6
Total Max. Power (W)
650
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
88.500%
Average Noise Output (>1450 Load Combinations)
33.42dBA
Average PF (>1450 Load Combinations)
0.983
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0489W
Non-Accredited
12V Ripple (Full Load)
12.53mV
5V Ripple (Full Load)
21.55mV
3.3V Ripple (Full Load)
24.35mV
5VSB Ripple (Full Load)
22.77mV
12V Load Regulation
0.67%
5V Load Regulation
1.48%
3.3V Load Regulation
2.07%
5VSB Load Regulation
2.33%
Inrush Current
65.592A
Accredited
Average Efficiency (>1450 load combinations)
90.166%
Average Noise Output (>1450 Load Combinations)
33.28dBA
Average PF (>1450 Load Combinations)
0.941
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0956W
Non-Accredited
12V Ripple (Full Load)
12.03mV
5V Ripple (Full Load)
20.24mV
3.3V Ripple (Full Load)
24.18mV
5VSB Ripple (Full Load)
21.22mV
12V Load Regulation
1.05%
5V Load Regulation
1.44%
3.3V Load Regulation
2.04%
5VSB Load Regulation
2.33%
Inrush Current
56.632A
Hold-Up Time & PWR_OK Signal
20.20ms
AC Loss to PWR_OK Hold Up Time
17.30ms
PWR_OK Inactive to DC Loss Delay
2.90ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
20.2
AC Loss to PWR_OK Hold Up Time (ms)
17.3
PWR_OK Inactive to DC Loss Delay (ms)
2.9
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.214
66.875%
0.032
5.112V
0.320
115.03V
2
0.087A
0.447
73.399%
0.060
5.111V
0.609
115.03V
3
0.542A
2.766
78.246%
0.255
5.100V
3.535
115.03V
4
1.002A
5.104
77.474%
0.338
5.093V
6.588
115.04V
5
1.502A
7.632
77.161%
0.386
5.082V
9.891
115.03V
6
3.002A
15.164
76.262%
0.444
5.052V
19.884
115.03V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.214
57.527%
0.011
5.112V
0.372
230.15V
2
0.087A
0.447
67.117%
0.020
5.111V
0.666
230.18V
3
0.543A
2.768
76.232%
0.102
5.101V
3.631
230.15V
4
1.002A
5.105
77.489%
0.168
5.093V
6.588
230.16V
5
1.502A
7.634
77.197%
0.224
5.083V
9.889
230.16V
6
3.002A
15.168
76.979%
0.316
5.053V
19.704
230.16V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.581A
1.995A
1.978A
0.981A
64.798
82.904%
860
24.7
32.56°C
0.978
12.072V
5.007V
3.333V
5.083V
78.160
35.81°C
115.07V
2
8.206A
2.995A
2.975A
1.181A
129.800
88.134%
885
26.3
33.12°C
0.982
12.058V
4.999V
3.324V
5.073V
147.276
36.87°C
115.06V
3
13.184A
3.508A
3.494A
1.381A
194.918
89.676%
945
28.6
34.26°C
0.976
12.047V
4.990V
3.318V
5.064V
217.359
38.47°C
115.06V
4
18.161A
4.014A
3.984A
1.581A
259.813
90.124%
1020
30.2
34.87°C
0.978
12.038V
4.984V
3.312V
5.054V
288.283
39.79°C
115.05V
5
22.803A
5.023A
4.992A
1.783A
324.765
90.045%
1100
32.5
35.88°C
0.983
12.029V
4.975V
3.303V
5.042V
360.669
41.51°C
115.05V
6
27.451A
6.039A
6.005A
1.986A
389.768
89.657%
1210
35.3
36.13°C
0.986
12.021V
4.968V
3.295V
5.031V
434.732
42.26°C
115.04V
7
32.098A
7.050A
7.023A
2.191A
454.620
89.080%
1282
37.0
36.75°C
0.989
12.012V
4.960V
3.288V
5.020V
510.350
44.33°C
115.05V
8
36.736A
8.075A
8.046A
2.395A
519.690
88.248%
1390
38.5
37.60°C
0.990
12.013V
4.953V
3.280V
5.008V
588.898
47.05°C
115.05V
9
41.833A
8.597A
8.583A
2.397A
584.798
87.582%
1470
40.4
38.88°C
0.991
12.005V
4.945V
3.273V
5.001V
667.712
48.64°C
115.04V
10
46.666A
9.112A
9.090A
3.008A
649.579
86.695%
1530
41.5
39.60°C
0.992
11.998V
4.938V
3.267V
4.983V
749.269
50.48°C
115.04V
11
52.102A
9.124A
9.108A
3.011A
714.495
85.806%
1545
42.2
40.26°C
0.993
11.992V
4.933V
3.260V
4.977V
832.683
52.39°C
115.04V
CL1
0.098A
16.026A
16.005A
0.005A
133.767
84.123%
1200
35.1
37.22°C
0.980
12.044V
4.972V
3.304V
5.082V
159.014
45.14°C
115.05V
CL2
61.943A
1.003A
1.004A
1.002A
756.739
85.831%
1550
42.7
39.48°C
0.993
11.999V
4.947V
3.274V
5.026V
881.666
49.45°C
115.05V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.567A
1.993A
1.978A
0.981A
64.787
83.557%
860
24.7
31.85°C
0.792
12.119V
5.007V
3.333V
5.083V
77.536
37.95°C
230.25V
2
8.185A
3.000A
2.976A
1.181A
129.769
89.106%
860
24.7
32.17°C
0.900
12.082V
4.998V
3.324V
5.073V
145.635
38.85°C
230.25V
3
13.164A
3.509A
3.492A
1.381A
194.900
90.799%
945
28.6
33.02°C
0.935
12.064V
4.990V
3.318V
5.064V
214.651
39.98°C
230.25V
4
18.138A
4.016A
3.983A
1.581A
259.779
91.381%
1000
29.8
33.52°C
0.950
12.051V
4.984V
3.312V
5.054V
284.282
40.78°C
230.23V
5
22.784A
5.020A
4.993A
1.782A
324.748
91.483%
1090
32.2
34.47°C
0.957
12.039V
4.975V
3.303V
5.042V
354.981
42.45°C
230.23V
6
27.420A
6.041A
6.007A
1.986A
389.660
91.321%
1170
33.9
35.09°C
0.963
12.030V
4.968V
3.295V
5.031V
426.691
43.71°C
230.24V
7
32.079A
7.053A
7.024A
2.191A
454.667
91.040%
1255
36.7
35.62°C
0.965
12.020V
4.960V
3.288V
5.020V
499.414
44.93°C
230.25V
8
36.736A
8.081A
8.047A
2.395A
519.678
90.625%
1340
37.8
36.54°C
0.968
12.012V
4.952V
3.280V
5.008V
573.436
46.28°C
230.23V
9
41.825A
8.598A
8.583A
2.398A
584.710
90.193%
1450
40.2
37.67°C
0.971
12.005V
4.945V
3.273V
5.001V
648.287
47.64°C
230.26V
10
46.667A
9.113A
9.091A
3.008A
649.553
89.582%
1525
41.3
39.06°C
0.973
11.997V
4.938V
3.267V
4.983V
725.091
49.50°C
230.24V
11
52.126A
9.124A
9.108A
3.011A
714.512
89.023%
1545
42.2
39.20°C
0.974
11.987V
4.932V
3.260V
4.977V
802.619
50.76°C
230.25V
CL1
0.098A
16.028A
16.002A
0.004A
133.749
85.300%
1190
34.7
36.58°C
0.911
12.063V
4.972V
3.303V
5.082V
156.799
44.64°C
230.24V
CL2
61.953A
1.003A
1.003A
1.002A
756.656
89.193%
1550
42.7
37.56°C
0.974
11.999V
4.947V
3.273V
5.026V
848.331
47.37°C
230.25V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.208A
0.490A
0.477A
0.196A
19.648
65.937%
750
21.3
0.882
12.086V
5.013V
3.338V
5.102V
29.798
115.07V
2
2.442A
0.989A
0.986A
0.391A
39.736
77.853%
810
23.3
0.953
12.079V
5.012V
3.336V
5.097V
51.040
115.07V
3
3.674A
1.486A
1.498A
0.586A
59.780
82.602%
820
23.8
0.970
12.074V
5.009V
3.334V
5.092V
72.371
115.07V
4
4.908A
1.995A
1.978A
0.786A
79.803
85.217%
830
24.4
0.973
12.068V
5.005V
3.332V
5.086V
93.647
115.07V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.194A
0.492A
0.476A
0.196A
19.622
58.584%
860
24.7
0.539
12.200V
5.012V
3.339V
5.103V
33.494
230.25V
2
2.421A
0.990A
0.989A
0.391A
39.757
71.875%
910
26.9
0.701
12.187V
5.010V
3.337V
5.097V
55.314
230.24V
3
3.664A
1.487A
1.498A
0.586A
59.843
83.353%
830
24.4
0.773
12.123V
5.008V
3.334V
5.092V
71.795
230.24V
4
4.892A
1.995A
1.979A
0.786A
79.800
86.007%
860
24.7
0.834
12.106V
5.005V
3.332V
5.086V
92.783
230.24V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.6 mV
10.0 mV
9.9 mV
7.5 mV
Pass
20% Load
7.5 mV
10.6 mV
11.4 mV
9.0 mV
Pass
30% Load
8.0 mV
12.3 mV
12.8 mV
11.0 mV
Pass
40% Load
9.3 mV
12.7 mV
13.5 mV
10.9 mV
Pass
50% Load
10.0 mV
13.6 mV
15.7 mV
14.0 mV
Pass
60% Load
11.6 mV
15.0 mV
16.9 mV
15.9 mV
Pass
70% Load
11.6 mV
15.5 mV
18.4 mV
18.8 mV
Pass
80% Load
10.4 mV
16.9 mV
19.1 mV
31.3 mV
Pass
90% Load
55.0 mV
25.8 mV
23.8 mV
31.5 mV
Pass
100% Load
12.5 mV
21.6 mV
24.4 mV
22.8 mV
Pass
110% Load
13.2 mV
21.9 mV
25.1 mV
23.3 mV
Pass
Crossload 1
7.9 mV
15.8 mV
17.8 mV
6.2 mV
Pass
Crossload 2
14.3 mV
19.0 mV
20.5 mV
20.2 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
11.6 mV
10.6 mV
10.6 mV
7.5 mV
Pass
20% Load
9.5 mV
11.0 mV
12.2 mV
8.7 mV
Pass
30% Load
9.2 mV
12.3 mV
13.9 mV
11.2 mV
Pass
40% Load
9.4 mV
13.5 mV
14.8 mV
11.7 mV
Pass
50% Load
9.5 mV
13.7 mV
16.7 mV
13.8 mV
Pass
60% Load
9.7 mV
15.0 mV
16.3 mV
15.4 mV
Pass
70% Load
10.1 mV
15.7 mV
18.1 mV
16.0 mV
Pass
80% Load
10.4 mV
16.8 mV
18.6 mV
26.3 mV
Pass
90% Load
11.0 mV
18.2 mV
20.3 mV
30.5 mV
Pass
100% Load
12.0 mV
20.2 mV
24.2 mV
21.2 mV
Pass
110% Load
13.4 mV
22.0 mV
23.7 mV
22.0 mV
Pass
Crossload 1
9.8 mV
15.5 mV
17.9 mV
5.9 mV
Pass
Crossload 2
14.1 mV
19.8 mV
20.4 mV
19.4 mV
Pass
The results above are not used in the certification process