| 115V | 230V | |
| Scheme: ETA-EMI PSU | ![]() |
![]() |
| 115V | 230V | |
![]() |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 36.0 °C | 0 RPM · <6.0 dB(A) · 50.3 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 38.8 °C | 0 RPM · <6.0 dB(A) · 51.4 °C | fan off in both |
| 50% | 0 RPM · <6.0 dB(A) · 45.2 °C | 718 RPM · 16.2 dB(A) · 42.4 °C | fan starts (<6.0 → 16.2) |
| 100% | 1864 RPM · 45.4 dB(A) · 30.6 °C | 1895 RPM · 45.5 dB(A) · 45.3 °C | +0.1 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 37.5 °C | 0 RPM · <6.0 dB(A) · 46.2 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 40.0 °C | 0 RPM · <6.0 dB(A) · 46.8 °C | fan off in both |
| 50% | 467 RPM · 8.3 dB(A) · 30.3 °C | 682 RPM · 14.9 dB(A) · 42.2 °C | +6.6 dB(A) |
| 100% | 1869 RPM · 45.4 dB(A) · 30.3 °C | 1896 RPM · 45.5 dB(A) · 46.0 °C | +0.1 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.