CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Enermax Platimax II 1200DF
Serial Number-
Lab IDEM12002985
Certification ID252985
  • Test Result Report ID: 25PS2985A
  • Certificate Issue Date: Oct 6, 2025
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 32.9 °C0 RPM · <6.0 dB(A) · 47.2 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 33.3 °C0 RPM · <6.0 dB(A) · 48.6 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 43.2 °C844 RPM · 22.3 dB(A) · 42.4 °Cfan starts (<6.0 → 22.3)
100%1231 RPM · 34.4 dB(A) · 30.9 °C1752 RPM · 44.3 dB(A) · 45.6 °C+9.9 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 30.5 °C0 RPM · <6.0 dB(A) · 40.7 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 31.5 °C0 RPM · <6.0 dB(A) · 41.0 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 32.9 °C732 RPM · 18.6 dB(A) · 42.3 °Cfan starts (<6.0 → 18.6)
100%1186 RPM · 33.1 dB(A) · 30.6 °C1737 RPM · 44.3 dB(A) · 45.5 °C+11.2 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests