CYBENETICS LTD 塞普勒斯 尼科西亞 拉齊亞 2231 Syrou 6號
Endorfy Vero L6 550W
序號EY7A0162508004029
Lab IDEY55003013
認證ID253013
  • 測試結果報告ID: 25PS3013A
  • 證書簽發日期: Oct 31, 2025
230V
認證方案:ETA-EMI PSU
230V
認證方案:LAMBDA PSU
驗證範圍之外
Aristeidis Bitziopoulos, 認證機構總經理

General Information

Test Equipment

DUT Information(Non-accredited measurements)

線材與接頭(Non-accredited measurements)

保護功能

電源規格

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary 230V

保持時間 & PWR_OK 訊號

待機功耗

Tables 230V

Graphs 230V

轉換效率圖表

230V

噪音圖

230V

Noise under high ambient temperature (indicative)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%597 RPM · <6.0 dB(A) · 30.7 °C641 RPM · 7.6 dB(A) · 40.5 °C<6.0 → 7.6 dB(A)
20%600 RPM · <6.0 dB(A) · 30.6 °C1008 RPM · 21.8 dB(A) · 40.5 °C<6.0 → 21.8 dB(A)
50%944 RPM · 20.0 dB(A) · 30.2 °C1572 RPM · 34.5 dB(A) · 42.3 °C+14.5 dB(A)
100%1717 RPM · 37.5 dB(A) · 30.6 °C1788 RPM · 38.0 dB(A) · 45.3 °C+0.5 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

傳導發射 EN 55032 & CISPR 32

Indicative Performance

高環溫電源轉換效率

5VSB效率

5VSB效率(ERP LOT 3/6與CEC) 230V

Protection Features

Supplementary Tests (For Reference)

典型負載測試 230V

輕載測試 230V

漣波測量 230V

Endorfy Vero L6 550W

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
本測試報告中包含的所有資料和圖表,任何個人在滿足以下條件時均可使用:
› 應註明測試結果由 Cybenetics 提供
› 在任何情況下均應提供原始測試結果文件的連結
Cybenetics為電源辦理自願性認證計畫——ETA針對效率、LAMBDA針對噪音、SAFE針對安全性與正常運作——同時也為散熱產品提供認證,其中DELTA針對機殼隔音,PHI針對風扇風量與靜壓。THETA在ISO 17065與認可範圍之外,對AMD AM5和Intel LGA1851平台上的散熱器效能進行評級。
CYBENETICS LTD 塞普勒斯 尼科西亞 拉齊亞 2231 Syrou 6號