This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
UVP (Full Load @ 180V)
✓
UVP (No Damage @ 170V)
✓
Conducted Emissions EN55032 & CISPR 32
✓
NLO
✓
Fan Failure Protection
✗
SIP
Surge: MOV Inrush: NTC & Bypass Relay
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
5.188A
1.976A
1.979A
1A
85.012
83.515%
914
<6.0
40.45°C
0.858
12.223V
5.061V
3.335V
4.999V
101.793
42.98°C
229.87V
20%
11.384A
2.968A
2.977A
1.204A
169.962
88.138%
919
<6.0
40.61°C
0.93
12.215V
5.055V
3.325V
4.984V
192.837
44.15°C
229.86V
30%
17.932A
3.467A
3.483A
1.409A
254.975
89.483%
924
<6.0
41.18°C
0.954
12.208V
5.048V
3.317V
4.969V
284.943
46.9°C
229.84V
40%
24.495A
3.968A
3.99A
1.615A
340.07
89.794%
934
<6.0
41.73°C
0.965
12.201V
5.041V
3.308V
4.955V
378.723
48.37°C
229.83V
50%
30.725A
4.968A
5.005A
1.823A
425.064
88.925%
1308
<6.0
42.36°C
0.971
12.190V
5.033V
3.297V
4.937V
478.01
49.61°C
229.81V
60%
36.906A
5.969A
6.023A
2A
509.301
89.139%
1328
<6.0
42.96°C
0.976
12.183V
5.027V
3.288V
4.924V
571.358
50.39°C
229.79V
70%
43.181A
6.973A
7.049A
2.242A
594.77
88.611%
1565
<6.0
43.42°C
0.98
12.174V
5.02V
3.278V
4.907V
671.219
50.8°C
229.78V
80%
49.471A
7.979A
8.079A
2.351A
679.587
87.897%
1766
<6.0
43.85°C
0.983
12.162V
5.013V
3.267V
4.893V
773.172
52.11°C
229.77V
90%
56.156A
8.491A
8.594A
2.459A
765.017
87.189%
1843
<6.0
44.71°C
0.985
12.154V
5.005V
3.258V
4.88V
877.422
53.96°C
229.75V
100%
62.595A
9.004A
9.143A
3.092A
849.815
86.354%
1844
<6.0
45.7°C
0.987
12.143V
4.998V
3.248V
4.853V
984.107
56.39°C
229.74V
110%
69.103A
10.018A
10.288A
3.1A
934.946
85.559%
1830
<6.0
46.4°C
0.98
12.108V
4.99V
3.236V
4.84V
1092.755
59.33°C
229.71V
CL1
0.115A
11.876A
12.001A
0.001A
101.307
73.397%
1268
<6.0
41.93°C
0.903
12.221V
5.069V
3.308V
5.008V
138.026
48.46°C
229.86V
CL2
0.115A
14.723A
0A
0A
76.401
73.518%
973
<6.0
41.79°C
0.862
12.228V
5.094V
3.322V
5.019V
103.923
47.85°C
229.87V
CL3
0.114A
0A
14.89A
0A
50.891
66.93%
919
<6.0
41.24°C
0.812
12.222V
5.043V
3.324V
5.019V
76.036
46.32°C
229.88V
CL4
69.965A
0.001A
0A
0.003A
849.603
87.242%
1854
<6.0
46.19°C
0.987
12.143V
4.996V
3.276V
4.951V
973.857
55.21°C
229.74V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.216A
0.494A
0.493A
0.199A
20.009
66.321%
887
<6.0
36.06°C
0.54
12.225V
5.066V
3.344V
5.027V
30.169
37.13°C
229.88V
40W
2.675A
0.691A
0.691A
0.299A
40.009
76.006%
899
<6.0
37.9°C
0.714
12.224V
5.064V
3.342V
5.023V
52.639
39.52°C
229.88V
60W
4.134A
0.889A
0.889A
0.399A
60.008
81.232%
903
<6.0
38.15°C
0.805
12.224V
5.063V
3.34V
5.018V
73.874
39.63°C
229.88V
80W
5.590A
1.087A
1.088A
0.499A
79.958
84.044%
907
<6.0
39.44°C
0.848
12.222V
5.061V
3.338V
5.013V
95.137
41.44°C
229.88V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.95mV
18.12mV
17.29mV
12.93mV
Pass
20% Load
19.59mV
17.29mV
17.24mV
13.14mV
Pass
30% Load
21.48mV
18.53mV
18.62mV
13.85mV
Pass
40% Load
24.34mV
18.68mV
19.96mV
15.24mV
Pass
50% Load
26.70mV
15.91mV
18.83mV
16.78mV
Pass
60% Load
31.81mV
20.22mV
21.80mV
18.88mV
Pass
70% Load
36.11mV
19.76mV
23.04mV
20.62mV
Pass
80% Load
40.46mV
22.27mV
28.37mV
22.17mV
Pass
90% Load
47.31mV
23.61mV
30.63mV
24.83mV
Pass
100% Load
51.27mV
26.94mV
32.77mV
28.38mV
Pass
110% Load
59.89mV
28.99mV
36.88mV
29.50mV
Pass
Crossload1
18.85mV
18.24mV
21.72mV
13.39mV
Pass
Crossload2
18.46mV
20.01mV
15.75mV
10.67mV
Pass
Crossload3
18.67mV
16.73mV
22.16mV
12.16mV
Pass
Crossload4
56.22mV
30.01mV
32.62mV
25.21mV
Pass
The results above are not used in the certification process
1st Player ACK 850W Bronze
Top side
Power specifications label
Fan
PSU Internals
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case