| 115V | 230V | |
| Scheme: ETA-EMI PSU | ![]() |
![]() |
| 115V | 230V | |
![]() |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 32.7 °C | 0 RPM · <6.0 dB(A) · 45.5 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 34.1 °C | 0 RPM · <6.0 dB(A) · 47.1 °C | fan off in both |
| 50% | 1186 RPM · 26.4 dB(A) · 30.4 °C | 591 RPM · <6.0 dB(A) · 42.5 °C | - |
| 100% | 1780 RPM · 39.0 dB(A) · 30.2 °C | 1606 RPM · 35.7 dB(A) · 45.3 °C | -3.3 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 32.0 °C | 0 RPM · <6.0 dB(A) · 49.7 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 32.9 °C | 0 RPM · <6.0 dB(A) · 50.3 °C | fan off in both |
| 50% | 568 RPM · 7.4 dB(A) · 30.2 °C | 596 RPM · 6.3 dB(A) · 42.4 °C | -1.1 dB(A) |
| 100% | 586 RPM · 6.5 dB(A) · 30.3 °C | 1618 RPM · 35.8 dB(A) · 45.6 °C | +29.3 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.