CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
MSI PRO A1000PL PCIE5
Serial Number3067ZPLX17HD810538000007
Lab IDMS10003058
Certification ID253058
  • Test Result Report ID: 25PS3058A
  • Certificate Issue Date: Dec 16, 2025
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

待機電源消耗

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

878889909192939495Average efficiency (%)88.8992.1892.0590.9689.4090.3993.9294.0393.4692.640-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 87115V230V
878889909192939495Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 87115V230V
0.900.920.940.960.981.00Average power factor0.9500.9840.9940.9960.9960.9210.9770.9910.9950.9950-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.90115V230V
0.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.90115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %233 / 23388.89%90.39%0.9500.921
20-<40 %310 / 31092.18%93.92%0.9840.977
40-<60 %310 / 31092.05%94.03%0.9940.991
60-<80 %310 / 31090.96%93.46%0.9960.995
80-100 %317 / 31789.40%92.64%0.9960.995
70-100 % (High-Load)472 / 47289.81%92.85%0.9960.995
All (published average)1480 / 148090.79%93.02%0.9860.979

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1480 (115V) and 1480 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 42.1 dB(A) at 115V and 41.9 dB(A) at 230V · loudest point 44.6 dB(A)
Efficiency 89.81% / 92.85% · power factor 0.996 / 0.995 (115V / 230V)
05101520253035404550Average noise (dB(A))33.233.20-<20 %fan off 0%/0%33.233.220-<40 %fan off 0%/0%34.334.440-<60 %fan off 0%/0%38.638.560-<80 %fan off 0%/0%43.042.880-100 %fan off 0%/0%115V230V
01020304050Average noise (dB(A))33.233.20-<20 %off 0%/0%33.233.220-<40 %off 0%/0%34.334.440-<60 %off 0%/0%38.638.560-<80 %off 0%/0%43.042.880-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %33.2 (35.0)33.2 (33.2)0% / 0%
20-<40 %33.2 (33.2)33.2 (33.2)0% / 0%
40-<60 %34.3 (37.1)34.4 (37.1)0% / 0%
60-<80 %38.6 (42.0)38.5 (42.0)0% / 0%
80-100 %43.0 (44.6)42.8 (43.9)0% / 0%
70-100 % (High-Load)42.1 (44.6)41.9 (43.9)0% / 0%
All (published average)38.5 (44.6)38.4 (43.9)0% / 0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1480 (115V) and 1480 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%1102 RPM · 33.1 dB(A) · 30.8 °C1119 RPM · 33.4 dB(A) · 40.2 °C+0.3 dB(A)
20%1109 RPM · 33.2 dB(A) · 30.5 °C1157 RPM · 34.3 dB(A) · 41.0 °C+1.1 dB(A)
50%1102 RPM · 33.1 dB(A) · 30.4 °C1422 RPM · 39.4 dB(A) · 42.2 °C+6.3 dB(A)
100%1682 RPM · 42.9 dB(A) · 30.5 °C2093 RPM · 47.9 dB(A) · 45.2 °C+5.0 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%1114 RPM · 33.3 dB(A) · 30.9 °C1162 RPM · 34.4 dB(A) · 40.4 °C+1.1 dB(A)
20%1115 RPM · 33.3 dB(A) · 30.2 °C1266 RPM · 36.5 dB(A) · 40.9 °C+3.2 dB(A)
50%1114 RPM · 33.3 dB(A) · 30.2 °C1457 RPM · 40.0 dB(A) · 42.0 °C+6.7 dB(A)
100%1736 RPM · 43.7 dB(A) · 30.8 °C2088 RPM · 47.8 dB(A) · 46.0 °C+4.1 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

MSI PRO A1000PL PCIE5

Top side
Top side
Power specifications label
Power specifications label
FAN
FAN
PSU INTERNAL
PSU INTERNAL
Cybenetics 提供自願性認證方案:電源供應器方面有 ETA(效率)、LAMBDA(噪音)與 SAFE(安全與正確運作);散熱產品方面有 DELTA(機殼隔音)與 PHI(風扇風量與靜壓)