| 115V | 230V | |
| Scheme: ETA-EMI PSU | ![]() |
![]() |
| 115V | 230V | |
![]() |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 40.2 °C | 0 RPM · <6.0 dB(A) · 46.0 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 43.8 °C | 0 RPM · <6.0 dB(A) · 50.7 °C | fan off in both |
| 50% | 0 RPM · <6.0 dB(A) · 50.0 °C | 0 RPM · <6.0 dB(A) · 65.3 °C | fan off in both |
| 100% | 669 RPM · <6.0 dB(A) · 30.1 °C | 2550 RPM · 42.0 dB(A) · 45.6 °C | <6.0 → 42.0 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 32.9 °C | 0 RPM · <6.0 dB(A) · 50.8 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 32.8 °C | 0 RPM · <6.0 dB(A) · 51.4 °C | fan off in both |
| 50% | 0 RPM · <6.0 dB(A) · 34.1 °C | 1087 RPM · 14.6 dB(A) · 42.4 °C | fan starts (<6.0 → 14.6) |
| 100% | 1872 RPM · 32.8 dB(A) · 31.0 °C | 2495 RPM · 41.1 dB(A) · 45.5 °C | +8.3 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.