CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
MSI MPG Ai1600TS PCIE5
Serial Number-
Lab IDMS16003107
Certification ID263107
  • Test Result Report ID: 26PS3107A
  • Certificate Issue Date: Feb 17, 2026
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

待機電源消耗

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

878889909192939495Average efficiency (%)88.5293.2192.9291.0489.2489.3393.4094.0593.4692.490-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 87115V230V
878889909192939495Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 87115V230V
0.800.820.840.860.880.900.920.940.960.981.00Average power factor0.9740.9930.9960.9970.9960.8380.9440.9650.9720.9750-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.80115V230V
0.800.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.80115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %263 / 26388.52%89.33%0.9740.838
20-<40 %320 / 32093.21%93.40%0.9930.944
40-<60 %320 / 32092.92%94.05%0.9960.965
60-<80 %320 / 32091.04%93.46%0.9970.972
80-100 %325 / 32589.24%92.49%0.9960.975
70-100 % (High-Load)485 / 48589.64%92.72%0.9960.974
All (published average)1548 / 154891.07%92.66%0.9920.943

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1548 (115V) and 1548 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1600 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages. 1 at 230V load combination has no valid power factor reading (zero, or above the possible maximum) and is left out of that average.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 24.5 dB(A) at 115V and 24.6 dB(A) at 230V · loudest point 32.4 dB(A)
Efficiency 89.64% / 92.72% · power factor 0.996 / 0.974 (115V / 230V)
05101520253035Average noise (dB(A))5.05.00-<20 %fan off 100%/100%5.05.020-<40 %fan off 30%/36%5.05.040-<60 %fan off 0%/0%13.413.360-<80 %fan off 0%/0%26.026.280-100 %fan off 0%/0%115V230V
0102030Average noise (dB(A))5.05.00-<20 %off 100%/100%5.05.020-<40 %off 30%/36%5.05.040-<60 %off 0%/0%13.413.360-<80 %off 0%/0%26.026.280-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %5.0 (5.0)5.0 (5.0)100% / 100%
20-<40 %5.0 (5.0)5.0 (5.0)30% / 36%
40-<60 %5.0 (5.0)5.0 (5.0)0% / 0%
60-<80 %13.4 (19.7)13.3 (19.7)0% / 0%
80-100 %26.0 (31.0)26.2 (32.4)0% / 0%
70-100 % (High-Load)24.5 (31.0)24.6 (32.4)0% / 0%
All (published average)19.6 (31.0)19.7 (32.4)23% / 24%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1548 (115V) and 1548 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1600 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 31.4 °C0 RPM · <6.0 dB(A) · 45.4 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 32.4 °C0 RPM · <6.0 dB(A) · 45.5 °Cfan off in both
50%441 RPM · 8.7 dB(A) · 30.8 °C458 RPM · <6.0 dB(A) · 42.1 °C-
100%1195 RPM · 30.9 dB(A) · 30.6 °C1486 RPM · 37.3 dB(A) · 45.3 °C+6.4 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 36.6 °C0 RPM · <6.0 dB(A) · 42.2 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 36.2 °C0 RPM · <6.0 dB(A) · 43.3 °Cfan off in both
50%439 RPM · 9.1 dB(A) · 30.8 °C462 RPM · <6.0 dB(A) · 42.4 °C-
100%1199 RPM · 30.9 dB(A) · 30.4 °C1490 RPM · 37.4 dB(A) · 47.0 °C+6.5 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

MSI MPG Ai1600TS PCIE5

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
Cybenetics 提供自願性認證方案:電源供應器方面有 ETA(效率)、LAMBDA(噪音)與 SAFE(安全與正確運作);散熱產品方面有 DELTA(機殼隔音)與 PHI(風扇風量與靜壓)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus