CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Cooler Master Elite Gold 1000W
Serial NumberCM1301000E41091301000013
Lab IDCM10003108
Certification ID263108
  • Test Result Report ID: 26PS3108A
  • Certificate Issue Date: Feb 20, 2026
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Vampire Power

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

8384858687888990919293Average efficiency (%)84.5890.0890.3989.3887.8085.8291.5792.2491.7790.860-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 83115V230V
8384858687888990919293Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 83115V230V
0.800.820.840.860.880.900.920.940.960.981.00Average power factor0.9220.9780.9900.9930.9930.8200.9370.9660.9760.9830-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.80115V230V
0.800.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.80115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %233 / 23384.58%85.82%0.9220.820
20-<40 %310 / 31090.08%91.57%0.9780.937
40-<60 %310 / 31090.39%92.24%0.9900.966
60-<80 %310 / 31089.38%91.77%0.9930.976
80-100 %317 / 31787.80%90.86%0.9930.983
70-100 % (High-Load)472 / 47288.20%91.09%0.9930.981
All (published average)1480 / 148088.64%90.69%0.9780.943

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1480 (115V) and 1480 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 39.0 dB(A) at 115V and 37.7 dB(A) at 230V · loudest point 45.1 dB(A)
Efficiency 88.20% / 91.09% · power factor 0.993 / 0.981 (115V / 230V)
05101520253035404550Average noise (dB(A))21.721.60-<20 %fan off 0%/0%21.721.720-<40 %fan off 0%/0%21.721.740-<60 %fan off 0%/0%23.423.160-<80 %fan off 0%/0%40.739.380-100 %fan off 0%/0%115V230V
01020304050Average noise (dB(A))21.721.60-<20 %off 0%/0%21.721.720-<40 %off 0%/0%21.721.740-<60 %off 0%/0%23.423.160-<80 %off 0%/0%40.739.380-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %21.7 (21.7)21.6 (21.7)0% / 0%
20-<40 %21.7 (21.7)21.7 (21.7)0% / 0%
40-<60 %21.7 (21.7)21.7 (21.7)0% / 0%
60-<80 %23.4 (36.6)23.1 (35.4)0% / 0%
80-100 %40.7 (45.1)39.3 (44.5)0% / 0%
70-100 % (High-Load)39.0 (45.1)37.7 (44.5)0% / 0%
All (published average)34.2 (45.1)32.9 (44.5)0% / 0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1480 (115V) and 1480 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%827 RPM · 20.6 dB(A) · 30.4 °C855 RPM · 21.9 dB(A) · 40.5 °C+1.3 dB(A)
20%832 RPM · 20.8 dB(A) · 30.3 °C859 RPM · 21.9 dB(A) · 40.7 °C+1.1 dB(A)
50%842 RPM · 21.4 dB(A) · 30.0 °C874 RPM · 22.2 dB(A) · 42.2 °C+0.8 dB(A)
100%1700 RPM · 40.0 dB(A) · 30.6 °C2129 RPM · 45.7 dB(A) · 45.4 °C+5.7 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%830 RPM · 20.7 dB(A) · 30.4 °C856 RPM · 21.9 dB(A) · 40.2 °C+1.2 dB(A)
20%835 RPM · 21.0 dB(A) · 30.4 °C859 RPM · 21.9 dB(A) · 40.9 °C+0.9 dB(A)
50%844 RPM · 21.5 dB(A) · 30.2 °C873 RPM · 22.2 dB(A) · 42.1 °C+0.7 dB(A)
100%1754 RPM · 41.0 dB(A) · 30.4 °C2127 RPM · 45.7 dB(A) · 45.3 °C+4.7 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Cooler Master Elite Gold 1000W

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics runs voluntary certification programs for power supplies - ETA for efficiency, LAMBDA for noise and SAFE for safety and correct operation - and for cooling products, with DELTA for chassis soundproofing and PHI for fan airflow and static pressure. THETA rates cooler performance on AMD AM5 and Intel LGA1851 outside ISO 17065 and accreditation scope
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus