CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
ASUS TUF GAMING 1200W Platinum
Serial Number-
Lab IDAS12003231
Certification ID263231
  • Test Result Report ID: 26PS3231A
  • Certificate Issue Date: Apr 15, 2026
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

868788899091929394Average efficiency (%)88.1791.9591.8190.5989.0687.8493.0993.5393.0392.160-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 86115V230V
868788899091929394Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 86115V230V
0.840.860.880.900.920.940.960.981.00Average power factor0.9540.9760.9880.9910.9930.8790.9460.9640.9720.9770-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.84115V230V
0.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.84115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %249 / 25088.17%87.84%0.9540.879
20-<40 %339 / 33991.95%93.09%0.9760.946
40-<60 %338 / 33791.81%93.53%0.9880.964
60-<80 %338 / 33890.59%93.03%0.9910.972
80-100 %342 / 34289.06%92.16%0.9930.977
70-100 % (High-Load)512 / 51289.45%92.38%0.9930.976
All (published average)1606 / 160690.43%92.15%0.9820.951

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1606 (115V) and 1606 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 31.2 dB(A) at 115V and 31.2 dB(A) at 230V · loudest point 36.8 dB(A)
Efficiency 89.45% / 92.38% · power factor 0.993 / 0.976 (115V / 230V)
0510152025303540Average noise (dB(A))<6.0<6.00-<20 %fan off 0%/0%<6.0<6.020-<40 %fan off 0%/0%<6.0<6.040-<60 %fan off 0%/0%19.119.160-<80 %fan off 0%/0%32.832.780-100 %fan off 0%/0%115V230V
010203040Average noise (dB(A))<6.0<6.00-<20 %off 0%/0%<6.0<6.020-<40 %off 0%/0%<6.0<6.040-<60 %off 0%/0%19.119.160-<80 %off 0%/0%32.832.780-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %<6.0 (<6.0)<6.0 (<6.0)0% / 0%
20-<40 %<6.0 (<6.0)<6.0 (<6.0)0% / 0%
40-<60 %<6.0 (8.6)<6.0 (8.6)0% / 0%
60-<80 %19.1 (26.2)19.1 (26.2)0% / 0%
80-100 %32.8 (36.8)32.7 (36.8)0% / 0%
70-100 % (High-Load)31.2 (36.8)31.2 (36.8)0% / 0%
All (published average)26.3 (36.8)26.2 (36.8)0% / 0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1606 (115V) and 1606 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%386 RPM · <6.0 dB(A) · 31.1 °C395 RPM · <6.0 dB(A) · 40.1 °C<6.0 in both
20%388 RPM · <6.0 dB(A) · 30.4 °C396 RPM · <6.0 dB(A) · 40.6 °C<6.0 in both
50%389 RPM · <6.0 dB(A) · 31.9 °C398 RPM · <6.0 dB(A) · 42.2 °C<6.0 in both
100%980 RPM · 25.9 dB(A) · 31.3 °C1408 RPM · 35.8 dB(A) · 45.4 °C+9.9 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%389 RPM · <6.0 dB(A) · 30.6 °C394 RPM · <6.0 dB(A) · 40.2 °C<6.0 in both
20%390 RPM · <6.0 dB(A) · 30.1 °C393 RPM · <6.0 dB(A) · 40.6 °C<6.0 in both
50%390 RPM · <6.0 dB(A) · 30.8 °C394 RPM · <6.0 dB(A) · 42.4 °C<6.0 in both
100%1396 RPM · 35.5 dB(A) · 31.8 °C1403 RPM · 35.7 dB(A) · 45.7 °C+0.2 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

ASUS TUF GAMING 1200W Platinum

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern