This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
UVP (Full Load @ 90V)
✓
UVP (No Damage @ 80V)
✓
Conducted Emissions EN55032 & CISPR 32
✓
NLO
✓
Fan Failure Protection
✗
SIP
Surge: MOV Inrush: NTC & Bypass Relay
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
4.414A
1.994A
1.996A
0.984A
75.004
85.081%
736
23.5
40.41°C
0.874
12.100V
5.014V
3.307V
5.082V
88.156
42.93°C
115.02V
20%
9.842A
2.993A
2.995A
1.183A
149.949
89.32%
739
23.5
40.74°C
0.937
12.096V
5.012V
3.305V
5.071V
167.879
45.4°C
114.99V
30%
15.624A
3.493A
3.496A
1.383A
224.955
90.463%
741
23.6
41.35°C
0.96
12.090V
5.01V
3.304V
5.061V
248.672
47.99°C
114.96V
40%
21.418A
3.994A
3.997A
1.584A
300.049
90.707%
745
23.5
41.69°C
0.972
12.086V
5.008V
3.303V
5.051V
330.788
50.63°C
114.94V
50%
26.819A
4.995A
4.999A
1.786A
374.502
90.405%
750
23.5
42.25°C
0.979
12.081V
5.006V
3.301V
5.039V
414.251
53.12°C
114.92V
60%
32.263A
5.997A
6.003A
1.989A
449.41
89.843%
756
23.1
42.81°C
0.982
12.076V
5.004V
3.299V
5.028V
500.218
57.87°C
114.89V
70%
37.714A
7A
7.008A
2.193A
524.353
89.239%
765
22.9
43.29°C
0.984
12.071V
5.001V
3.297V
5.017V
587.588
61.91°C
114.86V
80%
43.235A
8.001A
8.011A
2.297A
599.544
88.378%
1435
34.8
43.62°C
0.986
12.066V
4.999V
3.296V
5.008V
678.392
60.74°C
114.83V
90%
49.099A
8.502A
8.497A
2.4A
674.576
87.579%
1768
40.5
44.05°C
0.986
12.059V
4.998V
3.295V
5V
770.252
59.89°C
114.8V
100%
54.768A
9.006A
9.016A
3.013A
749.785
86.709%
1802
41.4
45.62°C
0.986
12.053V
4.996V
3.294V
4.979V
864.72
62.13°C
114.77V
110%
60.309A
10.012A
10.115A
3.017A
824.808
85.635%
1812
41.3
46.01°C
0.986
12.047V
4.993V
3.292V
4.972V
963.175
67.33°C
114.74V
CL1
0.116A
12.047A
12.044A
0A
101.298
80.547%
756
23.1
41.3°C
0.915
12.107V
4.996V
3.296V
5.092V
125.764
50.89°C
115.01V
CL2
0.116A
20.055A
0A
0A
101.343
78.406%
753
23.4
41.75°C
0.918
12.108V
4.983V
3.292V
5.096V
129.253
52.45°C
115.01V
CL3
0.115A
0A
20.057A
0A
67.403
72.22%
749
23.5
41.26°C
0.879
12.107V
5.004V
3.291V
5.096V
93.331
51.11°C
115.02V
CL4
62.222A
0A
0A
0A
749.604
87.627%
1804
41.4
45.47°C
0.987
12.047V
5.01V
3.298V
5.062V
855.453
62.24°C
114.77V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
4.414A
1.994A
1.995A
0.984A
75
86.556%
735
23.5
40.4°C
0.781
12.100V
5.015V
3.308V
5.083V
86.65
42.8°C
230V
20%
9.840A
2.992A
2.994A
1.183A
149.932
90.764%
737
23.6
40.92°C
0.869
12.096V
5.013V
3.306V
5.072V
165.187
44.05°C
229.99V
30%
15.622A
3.492A
3.494A
1.383A
224.93
92.018%
740
23.5
41.1°C
0.911
12.091V
5.011V
3.305V
5.062V
244.442
45.48°C
229.97V
40%
21.415A
3.993A
3.995A
1.584A
300.015
92.403%
745
23.5
41.72°C
0.934
12.086V
5.009V
3.304V
5.051V
324.682
47.63°C
229.96V
50%
26.808A
4.993A
4.996A
1.786A
374.387
92.352%
750
23.5
42.45°C
0.948
12.082V
5.007V
3.302V
5.04V
405.394
49.48°C
229.95V
60%
32.251A
5.995A
5.999A
1.988A
449.292
92.032%
756
23.1
42.64°C
0.957
12.077V
5.004V
3.301V
5.029V
488.189
52.31°C
229.93V
70%
37.711A
6.997A
7.001A
2.192A
524.318
91.624%
945
26.6
43.15°C
0.965
12.071V
5.003V
3.3V
5.017V
572.248
52.13°C
229.92V
80%
43.232A
7.998A
8.004A
2.296A
599.493
91.147%
1477
35.4
43.61°C
0.97
12.065V
5V
3.298V
5.009V
657.722
53.49°C
229.91V
90%
49.095A
8.501A
8.491A
2.4A
674.526
90.673%
1772
40.6
44.47°C
0.973
12.059V
4.998V
3.298V
5V
743.917
53.65°C
229.89V
100%
54.764A
9.004A
9.01A
3.013A
749.74
90.176%
1806
41.5
45.27°C
0.976
12.053V
4.997V
3.296V
4.979V
831.418
55.61°C
229.88V
110%
60.306A
10.01A
10.108A
3.017A
824.771
89.559%
1814
41.4
46.8°C
0.978
12.047V
4.994V
3.294V
4.972V
920.924
57.71°C
229.87V
CL1
0.116A
12.046A
12.037A
0A
101.293
82.067%
755
23.3
41.97°C
0.83
12.108V
4.997V
3.298V
5.093V
123.429
50.04°C
230V
CL2
0.116A
20.054A
0A
0A
101.343
79.779%
751
23.5
41.92°C
0.834
12.108V
4.984V
3.293V
5.096V
127.031
50.2°C
230V
CL3
0.114A
0A
20.024A
0A
67.399
73.542%
748
23.5
41.77°C
0.787
12.107V
5.005V
3.296V
5.096V
91.644
48.99°C
230V
CL4
62.227A
0A
0A
0A
749.606
90.951%
1806
41.5
45.3°C
0.975
12.047V
5.011V
3.301V
5.062V
824.188
54.74°C
229.88V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.227A
0.498A
0.499A
0.196A
19.997
68.782%
719
22.5
36.96°C
0.765
12.101V
5.017V
3.309V
5.107V
29.072
37.05°C
115.04V
40W
2.702A
0.698A
0.698A
0.294A
39.998
79.642%
725
23.0
37.45°C
0.818
12.100V
5.016V
3.308V
5.103V
50.223
38.03°C
115.03V
60W
4.176A
0.897A
0.898A
0.392A
59.999
84.333%
729
23.3
38.73°C
0.851
12.100V
5.016V
3.308V
5.099V
71.152
39.98°C
115.03V
80W
5.646A
1.097A
1.097A
0.491A
79.949
86.312%
733
23.5
39.45°C
0.88
12.099V
5.016V
3.308V
5.095V
92.633
41.76°C
115.02V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.227A
0.498A
0.499A
0.196A
19.998
69.507%
724
22.9
36.19°C
0.59
12.102V
5.018V
3.309V
5.107V
28.782
37.9°C
230.02V
40W
2.702A
0.698A
0.698A
0.294A
39.999
80.857%
726
23.2
37.9°C
0.69
12.101V
5.017V
3.308V
5.103V
49.469
39.16°C
230.01V
60W
4.176A
0.897A
0.898A
0.392A
59.999
85.387%
728
23.2
38.95°C
0.749
12.100V
5.017V
3.309V
5.099V
70.265
39.65°C
230V
80W
5.646A
1.096A
1.097A
0.491A
79.946
87.795%
730
23.4
39.3°C
0.788
12.099V
5.016V
3.309V
5.095V
91.062
41.29°C
230V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
30.44mV
25.19mV
23.48mV
22.51mV
Pass
20% Load
33.00mV
24.27mV
22.87mV
22.92mV
Pass
30% Load
35.25mV
25.39mV
23.94mV
23.22mV
Pass
40% Load
37.50mV
24.93mV
24.20mV
23.68mV
Pass
50% Load
36.83mV
24.62mV
25.22mV
24.20mV
Pass
60% Load
37.55mV
24.98mV
24.30mV
23.84mV
Pass
70% Load
36.73mV
24.83mV
23.99mV
24.25mV
Pass
80% Load
38.93mV
25.75mV
26.70mV
24.81mV
Pass
90% Load
40.21mV
26.31mV
27.11mV
25.11mV
Pass
100% Load
42.10mV
29.28mV
25.99mV
27.01mV
Pass
110% Load
42.31mV
28.46mV
27.83mV
29.00mV
Pass
Crossload1
32.80mV
25.19mV
26.09mV
24.76mV
Pass
Crossload2
33.00mV
28.25mV
25.06mV
22.71mV
Pass
Crossload3
30.13mV
24.67mV
29.21mV
24.35mV
Pass
Crossload4
40.98mV
26.47mV
25.78mV
28.95mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
27.57mV
23.76mV
22.15mV
23.94mV
Pass
20% Load
32.84mV
24.93mV
23.69mV
23.89mV
Pass
30% Load
34.68mV
24.47mV
23.33mV
23.28mV
Pass
40% Load
34.94mV
24.47mV
23.17mV
23.02mV
Pass
50% Load
36.32mV
24.17mV
24.15mV
23.43mV
Pass
60% Load
36.42mV
24.78mV
24.40mV
23.07mV
Pass
70% Load
36.27mV
23.81mV
23.58mV
23.37mV
Pass
80% Load
36.99mV
24.93mV
24.81mV
23.17mV
Pass
90% Load
38.73mV
24.42mV
25.63mV
24.25mV
Pass
100% Load
40.16mV
26.36mV
24.91mV
24.04mV
Pass
110% Load
41.80mV
26.36mV
25.27mV
24.60mV
Pass
Crossload1
31.62mV
23.86mV
24.45mV
24.35mV
Pass
Crossload2
31.10mV
27.54mV
24.96mV
24.91mV
Pass
Crossload3
27.78mV
23.04mV
27.63mV
25.27mV
Pass
Crossload4
39.24mV
24.83mV
23.02mV
28.28mV
Pass
The results above are not used in the certification process