General Information
Test Equipment
DUT Information
Cables and Connectors
Protection Features
Power Specifications
Parts Description
Test Results
Temperature & Compliance Info
Performance Summary
Hold-Up Time & PWR_OK Signal
待機電源消耗
Tables
Graphs
Efficiency Graph
Noise Graph
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
5VSB Efficiency
5VSB Efficiency (ERP LOT 3/6 & CEC)
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Light Load Tests
Ripple Measurements
Download
Great Wall CRPS2000C3
English
Deutsch
繁體中文
简体中文
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Great Wall CRPS2000C3
Serial Number
2Q030042096
Lab ID
GW20003316
Certification ID
263316
Test Result Report ID: 26PS3316A
Certificate Issue Date:
Oct 30, 2026
115V
230V
Scheme: ETA-EMI PSU
Aristeidis Bitziopoulos, Certification Body General Manager
General Information
Test Equipment
3316
Electronic Loads
Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources
Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers
Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes
Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer
Bruel & Kjaer 2270 G4
Microphone
Bruel & Kjaer Type 4955-A
Temperature Logger
Picoscope TC-08
Tachometer
UNI-T UT372
Multimeters
Keysight 34465A
EMI Analyzer
TekBox TBMR-110M-EU
Isolation Transformer
4kVA
UPS
FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology
Cybenetics PSU Test Protocol
DUT Information
(Non-accredited measurements)
dut-information
Product Identification Details
Brand
Great Wall
Model
CRPS2000C3
OEM/ODM
Great Wall
Serial Number
2Q030042096
Product Specifications
Manufacturer-Provided Information
Rated Voltage (Vrms)
100-127 / 200-240
Rated Current (Arms)
10
Rated Frequency (Hz)
50-60
Rated Power (W)
2000
Operating Temperature (Continuous Full Load) (°C)
0 ~ 55
Type
1U
Cable Design
Card edge connector (no cables)
Warranty
No info
Cybenetics Measurements
Dimensions (W x H x D)
73.5 x 40 x 185 mm
Weight
0.95 kg (2.09 lb)
Cooling
40 mm fan
Semi-Passive Operation
✗
Cybenetics Testing Information
Lab ID
GW20003316
Date of receipt
May 12, 2026
Testing Date
Oct 22, 2026
Report Issued Date
Oct 30, 2026
Engineer Name
Efstathios Papadopoulos
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors
(Non-accredited measurements)
3316
Cables And Connectors
Connector
Card Edge Connector (golden finger)
Captive Cables
None
Modular Cables
None
Power Specifications
3316
Rail
3.3V
5V
12V
12VSB
Max. Power
Amps
N/A
N/A
164
3
Watts
N/A
2000
36
Total Max. Power (W)
2000
Test Results
Temperature & Compliance Info
TRSub1
Temperature Range (°C /°F)
28-32 / 82.4-89.6
Conducted Emissions EN 55032 & CISPR 32
Passed
Performance Summary
230V
230V
Accredited
Average Efficiency (>1450 load combinations)
93.337%
Average PF (>1450 Load Combinations)
0.987
Efficiency With 10W (≤500W) or 2% (>500W) Load
78.919%
Standby Power Consumption
3.5033W
Non-Accredited
12V Ripple (Full Load)
114.10mV
12VSB Ripple (Full Load)
56.13mV
12V Load Regulation
3.76%
12VSB Load Regulation
3.35%
Hold-Up Time & PWR_OK Signal
15.70ms
AC Loss to PWR_OK Hold Up Time
14.30ms
PWR_OK Inactive to DC Loss Delay
1.40ms
Hold-Up Time & PWR_OK Signal
3316
Hold-Up Time (ms)
15.7
AC Loss to PWR_OK Hold Up Time (ms)
14.3
PWR_OK Inactive to DC Loss Delay (ms)
1.4
待機電源消耗
Tables
230V
230V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.02 V
230.01 V
227.70 V
230.05 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.15 %
0.13 %
N/A
0.17 %
2.00 %
PASS
Real Power:
3.503 W
3.056 W
N/A
3.971 W
N/A
N/A
Apparent Power:
22.179 W
21.718 W
N/A
22.646 W
N/A
N/A
Power Factor:
0.159
N/A
N/A
N/A
N/A
N/A
Graphs
230V
230V
Efficiency Graph
230V
230V
INFO
This graph depicts the PSU's efficiency throughout its tested 230V operational range.
Noise Graph
230V
230V
Conducted Emissions EN 55032 & CISPR 32
emi-data
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
und-hig-amb
INFO
The PSU's efficiency under high ambient temperature with 230V input.
12VSB Efficiency
5vsb-eff
INFO
This graph depicts the efficiency levels of the 12VSB rail at 230V input.
12VSB Efficiency (ERP LOT 3/6 & CEC)
230V
230V
Test #
12VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.019A
0.229W
6.081%
0.156
12.077V
3.766W
229.9V
2
0.038A
0.459W
11.329%
0.167
12.076V
4.052W
229.9V
3
0.4A
4.823W
54.373%
0.32
12.057V
8.87W
229.9V
4
0.625A
7.529W
62.936%
0.398
12.046V
11.963W
229.9V
5
1A
12.029W
69.647%
0.506
12.028V
17.271W
229.9V
6
3A
35.619W
79.884%
0.757
11.872V
44.588W
229.88V
Protection Features
3316
Supplementary Tests (For Reference)
Typical Load Tests
230V
230V
Test
12V
12VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
15.821A
0.415A
199.957W
93.702%
40.31°C
0.985
12.322V
12.045V
213.408W
41.4°C
229.85V
20%
32.027A
0.499A
399.47W
95.25%
40.39°C
0.995
12.286V
12.028V
419.421W
43.06°C
229.83V
30%
48.471A
0.583A
599.723W
95.319%
42.07°C
0.994
12.229V
12.012V
629.261W
45.51°C
229.79V
40%
64.989A
0.667A
799.981W
95.182%
41.56°C
0.996
12.186V
11.994V
840.484W
46.42°C
229.77V
50%
81.657A
0.751A
999.382W
94.599%
44.34°C
0.998
12.129V
11.977V
1056.493W
47.53°C
229.74V
60%
98.127A
0.836A
1199.63W
94.383%
42.24°C
0.999
12.123V
11.959V
1271W
47.51°C
229.71V
70%
114.968A
0.921A
1399.865W
93.517%
41.4°C
0.999
12.080V
11.941V
1496.812W
47.43°C
229.67V
80%
131.923A
0.964A
1599.577W
92.7%
44.12°C
1
12.038V
11.925V
1725.569W
49.11°C
229.62V
90%
149.070A
1.008A
1800.106W
92.191%
44.22°C
1
11.995V
11.908V
1952.785W
51.54°C
229.59V
100%
164.934A
3.082A
2000.138W
91.319%
44.89°C
1
11.909V
11.682V
2190.388W
54.42°C
229.55V
The results above are not used in the certification process
Light Load Tests
230V
230V
Test
12V
12VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
1.541A
0.083A
20.012W
73.432%
36.42°C
0.594
12.340V
12.073V
27.269W
38.5°C
0V
40W
3.116A
0.124A
40.008W
80.265%
36.54°C
0.786
12.356V
12.07V
49.851W
38.78°C
0V
60W
4.699A
0.166A
60.004W
82.85%
35.18°C
0.877
12.343V
12.067V
72.413W
37.32°C
0V
80W
6.273A
0.207A
79.928W
88.237%
35.12°C
0.914
12.343V
12.063V
90.591W
37.48°C
0V
The results above are not used in the certification process
Ripple Measurements
230V
230V
Test
12V
12VSB
Pass/Fail
10% Load
48.7 mV
28.6 mV
Pass
20% Load
56.2 mV
31.3 mV
Pass
30% Load
56.0 mV
33.9 mV
Pass
40% Load
63.4 mV
34.2 mV
Pass
50% Load
71.1 mV
35.9 mV
Pass
60% Load
73.0 mV
36.9 mV
Pass
70% Load
71.8 mV
39.7 mV
Pass
80% Load
84.4 mV
41.3 mV
Pass
90% Load
92.1 mV
42.4 mV
Pass
100% Load
114.1 mV
56.1 mV
Pass
The results above are not used in the certification process
Great Wall CRPS2000C3
Top side
Power specifications label
AC input, cooling fan, and release handle
Card-edge output connector
Cybenetics 提供自願性認證方案:電源供應器方面有 ETA(效率)、LAMBDA(噪音)與 SAFE(安全與正確運作);散熱產品方面有 DELTA(機殼隔音)與 PHI(風扇風量與靜壓)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
www.cybenetics.com
-
info@cybenetics.com
Cybenetics Product Assistant
Answers from public Cybenetics test data
×
Ask about Cybenetics-tested PSUs, fans, coolers, cases, capacitors and graphics cards.
Quiet 850W PSUs
Compare 120 mm fans
Your question
✓ Human verification completed
Reset
Ask