21.8A (109.00%), 4.78V *Voltage Drop (4.599V@22.2A)
21.3A (106.50%), 4.815V *Voltage Drop (4.558V@21.8A)
3.3V OCP (28.8°C / 40.9°C)
23.2A (116.00%), 3.135V *Voltage Drop (2.77V@23.9A)
22.8A (114.00%), 3.162V *Voltage Drop (2.737V@23.5A)
5VSB OCP (28.8°C / 40.9°C)
3.9A (130.00%), 4.938V
3.9A (130.00%), 4.937V
OPP (29.66°C / 43.02°C)
117.79%
110.41%
保持时间 & PG信号
Hold-Up Time (ms)
17.7
AC Loss to PWR_OK Hold Up Time (ms)
15.8
PWR_OK Inactive to DC Loss Delay (ms)
1.9
待机电源
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.98 V
114.95 V
113.85 V
114.99 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
60.00 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.13 %
0.10 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.062 W
0.011 W
N/A
0.086 W
N/A
N/A
Apparent Power:
6.631 W
6.606 W
N/A
6.655 W
N/A
N/A
Power Factor:
0.010
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.98 V
229.94 V
227.70 V
229.99 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.415
1.490
PASS
Mains Voltage THD:
0.14 %
0.12 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.147 W
0.097 W
N/A
0.202 W
N/A
N/A
Apparent Power:
21.205 W
21.166 W
N/A
21.242 W
N/A
N/A
Power Factor:
0.008
N/A
N/A
N/A
N/A
N/A
Graphs
转换效率图表
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input