The peripheral power cables use 20 AWG wire, which is thinner than the 18 AWG minimum specified in the ATX Power Supply Design Guide for peripheral/SATA connectors.
Engineer Name
Ioannis Kalyviotis
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
UVP (Typical Load @ 180V)
✓
UVP (No Damage @ 170V)
✓
NLO
✓
Fan Failure Protection
✗
SIP
Surge: MOV Inrush: NTC & Bypass Relay
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
2.744A
1.952A
1.987A
0.972A
54.998
83.045%
866
20.9
34.16°C
0.822
12.170V
5.122V
3.321V
5.145V
66.226
36.14°C
230.27V
20%
6.498A
2.937A
2.989A
1.168A
109.926
87.782%
865
20.9
34.95°C
0.899
12.162V
5.108V
3.313V
5.135V
125.227
37.79°C
230.26V
30%
10.610A
3.434A
3.495A
1.366A
164.919
89.173%
872
20.9
35.47°C
0.933
12.146V
5.097V
3.305V
5.126V
184.943
37.32°C
230.26V
40%
14.738A
3.933A
4.004A
1.563A
219.996
89.48%
1079
27.0
35.65°C
0.95
12.131V
5.085V
3.297V
5.117V
245.862
39.35°C
230.25V
50%
18.521A
4.931A
5.019A
1.762A
274.982
89.034%
1135
29.1
36.19°C
0.959
12.121V
5.07V
3.288V
5.108V
308.849
41.61°C
230.25V
60%
22.321A
5.935A
6.039A
1.962A
329.966
88.841%
1221
31.0
36.97°C
0.966
12.103V
5.055V
3.279V
5.097V
371.413
42.81°C
230.24V
70%
26.153A
6.946A
7.067A
2.162A
384.964
88.208%
1477
36.8
37.11°C
0.971
12.077V
5.04V
3.269V
5.087V
436.429
43.24°C
230.23V
80%
30.004A
7.96A
8.098A
2.264A
439.38
87.47%
1634
39.3
37.62°C
0.974
12.048V
5.024V
3.26V
5.078V
502.323
43.05°C
230.23V
90%
34.249A
8.479A
8.61A
2.366A
494.394
86.846%
1793
42.2
38.17°C
0.977
12.027V
5.012V
3.252V
5.07V
569.274
43.05°C
230.21V
100%
38.286A
9.001A
9.158A
2.968A
549.626
86.086%
2032
45.2
39.13°C
0.98
12.013V
4.999V
3.243V
5.053V
638.459
44.7°C
230.2V
110%
42.192A
10.033A
10.3A
2.972A
604.621
85.3%
2139
46.8
40.95°C
0.982
12.001V
4.983V
3.232V
5.046V
708.813
46.06°C
230.19V
CL1
0.113A
13.172A
13.299A
0A
111.275
82.394%
1042
26.4
34.55°C
0.911
12.161V
5.025V
3.286V
5.145V
135.052
43.23°C
230.27V
CL2
0.113A
20.011A
0A
0A
101.354
80.797%
888
21.6
35.32°C
0.903
12.170V
4.996V
3.307V
5.155V
125.442
43.53°C
230.27V
CL3
0.113A
0A
20.075A
0A
67.371
75.788%
873
20.9
34.31°C
0.867
12.161V
5.112V
3.287V
5.15V
88.894
41.21°C
230.28V
CL4
45.709A
0A
0A
0A
549.489
87.016%
1804
42.3
39.04°C
0.979
12.022V
5.077V
3.27V
5.119V
631.479
41.66°C
230.2V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.220A
0.486A
0.495A
0.194A
19.992
68.608%
829
19.5
30.17°C
0.626
12.170V
5.139V
3.331V
5.16V
29.14
32.42°C
230.28V
40W
2.686A
0.682A
0.694A
0.291A
39.994
80.081%
855
21.1
31.55°C
0.766
12.168V
5.135V
3.327V
5.159V
49.942
33.5°C
230.28V
60W
4.153A
0.877A
0.893A
0.388A
60.001
84.324%
858
21.1
32.41°C
0.834
12.167V
5.131V
3.325V
5.155V
71.155
34.21°C
230.25V
80W
5.614A
1.073A
1.093A
0.485A
79.94
86.578%
868
20.9
33.12°C
0.87
12.168V
5.127V
3.321V
5.152V
92.333
36.12°C
230.25V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
27.32mV
24.57mV
24.30mV
14.92mV
Pass
20% Load
30.16mV
25.35mV
25.49mV
16.41mV
Pass
30% Load
31.66mV
27.51mV
24.15mV
16.62mV
Pass
40% Load
33.67mV
26.12mV
25.50mV
16.67mV
Pass
50% Load
37.64mV
28.13mV
24.72mV
17.40mV
Pass
60% Load
41.50mV
30.34mV
30.04mV
17.91mV
Pass
70% Load
45.37mV
29.21mV
30.51mV
18.94mV
Pass
80% Load
48.41mV
30.40mV
25.86mV
19.82mV
Pass
90% Load
52.07mV
29.31mV
26.11mV
21.37mV
Pass
100% Load
60.43mV
31.68mV
28.54mV
27.67mV
Pass
110% Load
65.22mV
33.33mV
28.80mV
29.94mV
Pass
Crossload1
30.16mV
31.94mV
36.46mV
15.02mV
Pass
Crossload2
32.17mV
41.52mV
37.91mV
16.88mV
Pass
Crossload3
27.99mV
26.38mV
38.68mV
14.35mV
Pass
Crossload4
36.04mV
29.42mV
30.20mV
19.56mV
Pass
The results above are not used in the certification process
TEXTORM TX550+
Top side
Power specifications label
Fan
PSU Internals
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics runs voluntary certification programs for power supplies - ETA for efficiency, LAMBDA for noise and SAFE for safety and correct operation - and for cooling products, with DELTA for chassis soundproofing and PHI for fan airflow and static pressure