The peripheral power cables use 20 AWG wire, which is thinner than the 18 AWG minimum specified in the ATX Power Supply Design Guide for peripheral/SATA connectors. Lower than 60% efficiency at 2% load @ 230V.
Engineer Name
Ioannis Kalyviotis
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
UVP (Typical Load @ 90V)
✓
UVP (No Damage @ 80V)
✓
Conducted Emissions EN55032 & CISPR 32
✓
NLO
✓
Fan Failure Protection
✗
SIP
Surge: MOV Inrush: NTC & Bypass Relay
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
1.929A
1.946A
1.982A
0.977A
44.989
80.453%
817
19.3
34.35°C
0.796
12.126V
5.139V
3.33V
5.114V
55.92
35.17°C
230.3V
20%
4.898A
2.926A
2.979A
1.175A
89.997
86.251%
815
19.3
34.83°C
0.897
12.066V
5.125V
3.323V
5.104V
104.342
36.65°C
230.3V
30%
8.229A
3.421A
3.481A
1.374A
134.902
88.14%
817
19.3
35.11°C
0.936
12.014V
5.115V
3.318V
5.094V
153.055
38.06°C
230.29V
40%
11.586A
3.918A
3.986A
1.573A
179.979
88.765%
817
19.3
35.71°C
0.956
11.978V
5.104V
3.312V
5.084V
202.758
39.59°C
230.27V
50%
14.574A
4.912A
4.992A
1.774A
224.967
88.757%
825
19.5
36.12°C
0.964
11.971V
5.09V
3.305V
5.073V
253.464
41.58°C
230.27V
60%
17.572A
5.911A
6.004A
1.975A
269.955
88.473%
840
20.1
36.67°C
0.971
11.959V
5.076V
3.298V
5.063V
305.127
44.15°C
230.25V
70%
20.615A
6.917A
7.02A
2.177A
314.944
87.796%
1245
31.3
37.37°C
0.976
11.925V
5.06V
3.291V
5.051V
358.721
47.55°C
230.24V
80%
23.673A
7.925A
8.04A
2.28A
359.966
87.144%
1424
35.4
37.71°C
0.979
11.916V
5.046V
3.283V
5.043V
413.069
48.47°C
230.24V
90%
27.069A
8.439A
8.545A
2.383A
404.719
86.487%
1560
38.1
38.76°C
0.981
11.904V
5.035V
3.276V
5.034V
467.951
48.99°C
230.23V
100%
30.245A
8.956A
9.084A
2.991A
449.531
85.769%
1756
41.2
39.54°C
0.984
11.898V
5.024V
3.269V
5.014V
524.118
51.12°C
230.22V
110%
33.280A
9.984A
10.209A
2.996A
494.163
84.939%
2000
44.8
40.06°C
0.985
11.895V
5.007V
3.261V
5.007V
581.789
53.68°C
230.22V
CL1
0.114A
11.92A
11.988A
0A
101.267
82.531%
870
20.9
34.72°C
0.918
12.045V
5.05V
3.311V
5.119V
122.703
43.91°C
230.28V
CL2
0.114A
19.939A
0A
0A
101.35
80.771%
854
21.1
34.73°C
0.92
12.047V
5.014V
3.315V
5.126V
125.478
42.28°C
230.28V
CL3
0.114A
0A
19.869A
0A
67.37
75.547%
839
20.1
34.95°C
0.876
12.075V
5.121V
3.321V
5.122V
89.175
39.85°C
230.29V
CL4
37.715A
0A
0A
0A
449.401
86.953%
1447
36.0
39.58°C
0.982
11.916V
5.1V
3.287V
5.099V
516.833
46.85°C
230.23V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.220A
0.485A
0.495A
0.195A
19.988
68.506%
797
18.4
30.07°C
0.614
12.157V
5.155V
3.336V
5.136V
29.177
31.62°C
230.32V
40W
2.694A
0.679A
0.693A
0.292A
39.99
79.62%
806
18.6
31.09°C
0.769
12.128V
5.151V
3.333V
5.132V
50.225
32.9°C
230.31V
60W
4.176A
0.874A
0.892A
0.39A
59.99
83.909%
806
18.6
32.24°C
0.844
12.100V
5.147V
3.331V
5.127V
71.494
33.54°C
230.3V
80W
5.656A
1.069A
1.09A
0.488A
79.925
86.164%
809
18.6
33.11°C
0.88
12.076V
5.142V
3.328V
5.123V
92.76
35.37°C
230.3V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
22.22mV
22.41mV
38.01mV
13.32mV
Pass
20% Load
23.61mV
24.68mV
34.96mV
13.63mV
Pass
30% Load
26.04mV
26.12mV
36.09mV
15.02mV
Pass
40% Load
29.70mV
26.58mV
29.06mV
16.26mV
Pass
50% Load
31.30mV
26.69mV
26.22mV
16.05mV
Pass
60% Load
35.98mV
27.92mV
32.16mV
16.98mV
Pass
70% Load
38.67mV
27.61mV
33.10mV
16.16mV
Pass
80% Load
44.44mV
33.44mV
30.04mV
18.53mV
Pass
90% Load
51.92mV
33.18mV
34.23mV
20.08mV
Pass
100% Load
54.55mV
33.59mV
35.57mV
29.68mV
Pass
110% Load
60.84mV
35.60mV
44.37mV
33.34mV
Pass
Crossload1
25.62mV
29.78mV
37.49mV
14.25mV
Pass
Crossload2
29.96mV
40.90mV
26.63mV
16.72mV
Pass
Crossload3
27.58mV
25.19mV
21.47mV
14.14mV
Pass
Crossload4
48.98mV
29.62mV
41.57mV
15.64mV
Pass
The results above are not used in the certification process
TEXTORM TX450+
Top side
Power specifications label
Fan
PSU Internals
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics runs voluntary certification programs for power supplies - ETA for efficiency, LAMBDA for noise and SAFE for safety and correct operation - and for cooling products, with DELTA for chassis soundproofing and PHI for fan airflow and static pressure