CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
ASUS TUF Gaming EVO 1200W
Serial Number-
Lab IDAS12003380
Certification ID263380
  • Test Result Report ID: 26PS3380A
  • Certificate Issue Date: Aug 7, 2026
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Vampire Power

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

84858687888990919293Average efficiency (%)85.6990.9591.0189.9088.4186.6792.2992.9192.4591.580-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 84115V230V
84858687888990919293Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 84115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0.9700.9900.9910.9950.9970.8400.9390.9620.9720.9770-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %229 / 22885.69%86.67%0.9700.840
20-<40 %310 / 31190.95%92.29%0.9900.939
40-<60 %310 / 30991.01%92.91%0.9910.962
60-<80 %310 / 31189.90%92.45%0.9950.972
80-100 %315 / 31588.41%91.58%0.9970.977
70-100 % (High-Load)470 / 47188.78%91.81%0.9960.976
All (published average)1474 / 147489.38%91.44%0.9890.944

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1474 (115V) and 1474 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages. 1 at 230V load combination has no valid efficiency reading (zero, or above the possible maximum) and is left out of that average.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 30.4 dB(A) at 115V and 30.8 dB(A) at 230V · loudest point 39.6 dB(A)
Efficiency 88.78% / 91.81% · power factor 0.996 / 0.976 (115V / 230V)
0510152025303540Average noise (dB(A))<6.0<6.00-<20 %fan off 0%/0%<6.0<6.020-<40 %fan off 0%/0%<6.0<6.040-<60 %fan off 0%/0%12.312.160-<80 %fan off 0%/0%32.132.580-100 %fan off 0%/0%115V230V
010203040Average noise (dB(A))<6.0<6.00-<20 %off 0%/0%<6.0<6.020-<40 %off 0%/0%<6.0<6.040-<60 %off 0%/0%12.312.160-<80 %off 0%/0%32.132.580-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %<6.0 (<6.0)<6.0 (<6.0)0% / 0%
20-<40 %<6.0 (<6.0)<6.0 (<6.0)0% / 0%
40-<60 %<6.0 (<6.0)<6.0 (<6.0)0% / 0%
60-<80 %12.3 (23.8)12.1 (23.8)0% / 0%
80-100 %32.1 (39.6)32.5 (39.6)0% / 0%
70-100 % (High-Load)30.4 (39.6)30.8 (39.6)0% / 0%
All (published average)25.5 (39.6)25.9 (39.6)0% / 0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1474 (115V) and 1474 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

ASUS TUF Gaming EVO 1200W

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics runs voluntary certification programs for power supplies - ETA for efficiency, LAMBDA for noise and SAFE for safety and correct operation - and for cooling products, with DELTA for chassis soundproofing and PHI for fan airflow and static pressure. THETA rates cooler performance on AMD AM5 and Intel LGA1851 outside ISO 17065 and accreditation scope
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus