Model: RPS0242
OCP per pin test – 12V-2x6 connector
- At 9.90 A, the PSU shut down after about 20 seconds.
- At 18 A, the PSU shut down immediately.
- Result: works as expected (delayed trip at low overload, instant trip at high overload).
Engineer Name
Efstathios Papadopoulos
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
线材与接头(Non-accredited measurements)
模组化线材
描述
线材数量
总连接器数量
Gauge
Cable Type
ATX 接头 20+4 pin (610mm)
1
1
16-20AWG
Tinned Copper
4+4 pin EPS 12V 接头 (650mm)
2
2
18AWG
Tinned Copper
6+2pin PCIe接头 (650mm)
2
2
18AWG
Tinned Copper
2x 6+2pin PCIe接头 (640mm)
1
2
18AWG
Tinned Copper
12+2 pin PCIe (640mm) (600W)
1
1
16-24AWG
Tinned Copper
SATA接头 (450mm+115mm+115mm+115mm)
2
8
18AWG
Tinned Copper
4-pin Molex (445mm+100mm+100mm+100mm)
2
8
18AWG
Tinned Copper
AC Power Cord (1400mm) - C13 coupler
1
1
16AWG
-
iCUE LINK cable (2x 90 deg. connector) (135mm)
1
1
-
-
iCUE LINK cable (straight to 90 deg. connector) (600mm)
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input