CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
ABKO COREMAX 700W BRONZE
Serial Number-
Lab IDAB70003397
Certification ID263397
  • Test Result Report ID: 26PS3397A
  • Certificate Issue Date: Sep 3, 2026
115V
Scheme: ETA-EMI PSU
115V
Scheme: LAMBDA PSU
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary 115V

Hold-Up Time & PWR_OK Signal

待機電源消耗

Tables 115V

Graphs 115V

Efficiency Graph

115V

Efficiency and power factor by load range

798081828384858687Average efficiency (%)80.4785.4486.2285.4983.930-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 79115V
798081828384858687Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 79115V
0.940.960.981.00Average power factor0.9650.9650.9760.9820.9860-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.94115V
0.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.94115V
Load rangePointsEfficiency
115V
PF
115V
0-<20 %18580.47%0.965
20-<40 %36285.44%0.965
40-<60 %36186.22%0.976
60-<80 %36285.49%0.982
80-100 %37183.93%0.986
70-100 % (High-Load)55184.35%0.985
All (published average)164184.72%0.976

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1641 (115V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 700 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

115V

Noise by load range

High-Load Index (70-100 % load)
Noise 45.8 dB(A) at 115V · loudest point 45.8 dB(A)
Efficiency 84.35% · power factor 0.985 (115V)
0510152025303540455055Average noise (dB(A))26.30-<20 %fan off 0%34.720-<40 %fan off 0%43.440-<60 %fan off 0%45.860-<80 %fan off 0%45.880-100 %fan off 0%115V
01020304050Average noise (dB(A))26.30-<20 %off 0%34.720-<40 %off 0%43.440-<60 %off 0%45.860-<80 %off 0%45.880-100 %off 0%115V
Load rangeNoise 115V
avg (loudest)
Fan off
115V
0-<20 %26.3 (37.8)0%
20-<40 %34.7 (45.4)0%
40-<60 %43.4 (45.8)0%
60-<80 %45.8 (45.8)0%
80-100 %45.8 (45.8)0%
70-100 % (High-Load)45.8 (45.8)0%
All (published average)43.5 (45.8)0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1641 (115V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 700 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%768 RPM · 17.9 dB(A) · 30.3 °C747 RPM · 17.4 dB(A) · 34.1 °C-0.5 dB(A)
20%746 RPM · 17.1 dB(A) · 30.1 °C754 RPM · 17.4 dB(A) · 34.9 °C+0.3 dB(A)
50%1550 RPM · 39.8 dB(A) · 29.1 °C1856 RPM · 46.0 dB(A) · 36.4 °C+6.2 dB(A)
100%1853 RPM · 46.0 dB(A) · 30.8 °C1872 RPM · 46.3 dB(A) · 39.5 °C+0.3 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC) 115V

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests 115V

Light Load Tests 115V

Ripple Measurements 115V

ABKO COREMAX 700W BRONZE

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
Cybenetics 提供自願性認證方案:電源供應器方面有 ETA(效率)、LAMBDA(噪音)與 SAFE(安全與正確運作);散熱產品方面有 DELTA(機殼隔音)與 PHI(風扇風量與靜壓)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus