| Average Efficiency (>1450 load combinations) | 92.132% |
| Average Noise Output (>1450 Load Combinations) | 30.44dBA |
| Average PF (>1450 Load Combinations) | 0.957 |
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 73.211% |
| Standby Power Consumption | 0.1179W |
| 12V Ripple (Full Load) | 54.85mV |
| 5V Ripple (Full Load) | 43.53mV |
| 3.3V Ripple (Full Load) | 47.32mV |
| 5VSB Ripple (Full Load) | 36.18mV |
| 12V Load Regulation | 0.08% |
| 5V Load Regulation | 0.32% |
| 3.3V Load Regulation | 0.69% |
| 5VSB Load Regulation | 4.77% |
| Inrush Current | 74.370A |
| 12V Transient Response (200%) | 11.29V |
| 5V Transient Response (200%) | 4.905V |
| 3.3V Transient Response (200%) | 3.191V |
| 5VSB Transient Response (200%) | 4.869V |
| Hold-Up Time & PWR_OK Signal | 16.90ms |
| AC Loss to PWR_OK Hold Up Time | 13.10ms |
| PWR_OK Inactive to DC Loss Delay | 3.80ms |
| PSU Timings: T1 (20% / 100%) | 63.0ms | 62.0ms |
| PSU Timings: T3 (20% / 100%) | 115.0ms | 115.0ms |
| 12V OCP (29.6°C / 42.2°C) | 121.100A (121.10%), 12.036V — shut down | 121.000A (121.00%), 12.038V — shut down |
| 5V OCP (29.6°C / 42.2°C) | 29.500A (147.50%), 5.041V — shut down | 28.400A (142.00%), 5.041V — shut down |
| 3.3V OCP (29.6°C / 42.2°C) | 29.200A (146.00%), 3.322V — shut down | 28.700A (143.50%), 3.322V — shut down |
| 5VSB OCP (29.6°C / 42.2°C) | 5.100A (170.00%), 4.920V — shut down | 5.000A (166.67%), 4.919V — shut down |
| OPP (29.05°C / 41.90°C) | 121.34% | 119.63% |