CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Micronics Wizmax P-1200W
Serial Number-
Lab IDMI12003425
Certification ID263425
  • Test Result Report ID: 26PS3425A
  • Certificate Issue Date: Sep 24, 2026
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
This product certification body is accredited by CYS-CYSAB (Cyprus Accreditation Body) under accreditation number C010 as a Product Certification Body, in accordance with the recognized International Standard ISO/IEC 17065:2012 “Conformity assessment — Requirements for bodies certifying products, processes and services”. The accreditation covers the ETA and LAMBDA certification of power supply units and of multimedia (information technology) equipment, and the PHI certification of cooling fans, each as a Type 1a scheme according to ISO/IEC 17067. Certifications outside that scope are not covered by the accreditation. This accreditation demonstrates technical competence for a defined scope and the operation of a management system.
Aristeidis Bitziopoulos, Certification Body General Manager
CYS-CYSAB accreditation symbol, ISO/IEC 17065:2012
No. of Accred.: C010
PRODUCT CERTIFICATION

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

待機電源消耗

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

868788899091929394Average efficiency (%)87.9091.7891.7890.3888.9587.1492.5493.1992.8492.020-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 86115V230V
868788899091929394Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 86115V230V
0.860.880.900.920.940.960.981.00Average power factor0.9680.9840.9920.9940.9950.8870.9580.9730.9790.9820-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.86115V230V
0.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.86115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %228 / 22887.90%87.14%0.9680.887
20-<40 %310 / 31091.78%92.54%0.9840.958
40-<60 %310 / 31091.78%93.19%0.9920.973
60-<80 %310 / 31090.38%92.84%0.9940.979
80-100 %316 / 31688.95%92.02%0.9950.982
70-100 % (High-Load)471 / 47189.29%92.23%0.9950.982
All (published average)1474 / 147490.28%91.79%0.9870.960

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1474 (115V) and 1474 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 30.9 dB(A) at 115V and 31.0 dB(A) at 230V · loudest point 37.7 dB(A)
Efficiency 89.29% / 92.23% · power factor 0.995 / 0.982 (115V / 230V)
0510152025303540Average noise (dB(A))<6.0<6.00-<20 %fan off 0%/0%<6.0<6.020-<40 %fan off 0%/0%<6.0<6.040-<60 %fan off 0%/0%15.315.060-<80 %fan off 0%/0%32.632.780-100 %fan off 0%/0%115V230V
010203040Average noise (dB(A))<6.0<6.00-<20 %off 0%/0%<6.0<6.020-<40 %off 0%/0%<6.0<6.040-<60 %off 0%/0%15.315.060-<80 %off 0%/0%32.632.780-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %<6.0 (<6.0)<6.0 (<6.0)0% / 0%
20-<40 %<6.0 (<6.0)<6.0 (<6.0)0% / 0%
40-<60 %<6.0 (<6.0)<6.0 (<6.0)0% / 0%
60-<80 %15.3 (22.9)15.0 (22.9)0% / 0%
80-100 %32.6 (37.7)32.7 (37.7)0% / 0%
70-100 % (High-Load)30.9 (37.7)31.0 (37.7)0% / 0%
All (published average)26.0 (37.7)26.1 (37.7)0% / 0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1474 (115V) and 1474 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%313 RPM · <6.0 dB(A) · 30.1 °C321 RPM · <6.0 dB(A) · 40.2 °C<6.0 in both
20%313 RPM · <6.0 dB(A) · 30.1 °C322 RPM · <6.0 dB(A) · 40.8 °C<6.0 in both
50%313 RPM · <6.0 dB(A) · 30.5 °C324 RPM · <6.0 dB(A) · 42.2 °C<6.0 in both
100%313 RPM · <6.0 dB(A) · 31.0 °C1382 RPM · 38.3 dB(A) · 45.8 °C<6.0 → 38.3 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%313 RPM · <6.0 dB(A) · 30.7 °C322 RPM · <6.0 dB(A) · 40.3 °C<6.0 in both
20%318 RPM · <6.0 dB(A) · 30.7 °C322 RPM · <6.0 dB(A) · 40.9 °C<6.0 in both
50%319 RPM · <6.0 dB(A) · 30.5 °C341 RPM · <6.0 dB(A) · 42.3 °C<6.0 in both
100%1274 RPM · 36.3 dB(A) · 32.0 °C1434 RPM · 39.2 dB(A) · 45.1 °C+2.9 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Micronics Wizmax P-1200W

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
Cybenetics 提供自願性認證方案:電源供應器方面有 ETA(效率)、LAMBDA(噪音)與 SAFE(安全與正確運作);散熱產品方面有 DELTA(機殼隔音)與 PHI(風扇風量與靜壓)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus